Suppr超能文献

放射学中的非离子型造影剂。操作注意事项。

Nonionic contrast media in radiology. Procedural considerations.

作者信息

Robertson H J

机构信息

Section of Neuroradiology, Louisiana State University Medical Center, New Orleans.

出版信息

Invest Radiol. 1988 Nov;23 Suppl 2:S374-7. doi: 10.1097/00004424-198811002-00011.

Abstract

Reports of thrombus formation or embolism during angiography with nonionic contrast media were reviewed. Several factors were identified that may contribute to blood clot formation within or on the surface of angiographic catheters. Nonionic contrast media have a mild anticoagulant effect in vitro and in vivo. Careful and correct angiographic techniques are necessary to effectively use the nonionic contrast substances. As a basic principle, blood should not be mixed with the contrast agent prior to intravascular injection. Frequent flushing of the angiographic catheter with heparinized saline is recommended.

摘要

对使用非离子型造影剂进行血管造影期间血栓形成或栓塞的报告进行了综述。确定了几个可能导致血管造影导管内或表面形成血凝块的因素。非离子型造影剂在体外和体内具有轻微的抗凝作用。要有效使用非离子型造影剂,必须采用仔细且正确的血管造影技术。作为基本原则,在血管内注射前血液不应与造影剂混合。建议用肝素化盐水频繁冲洗血管造影导管。