Garcia-Arguello Segundo Francisco, Lopez-Lorenzo Beatriz, Ruiz-Cruces Rafael
Centro de Investigaciones Médico-Sanitarias, Fundación General Universidad de Málaga, Málaga, Spain.
Grupo de Arteriosclerosis, Prevención Cardiovascular y Metabolismo, Instituto de Investigación Biomédica de Málaga (IBIMA), Málaga, Spain.
J Labelled Comp Radiopharm. 2019 Mar;62(3):146-153. doi: 10.1002/jlcr.3706. Epub 2019 Feb 5.
The interest in gallium-68 labelled positron-emission tomography probes continues to increase around the world. However, one of the barriers for routine clinical use is the cost of the automated synthesis units for relatively simple labelling procedures. Herein, we describe the adaptation of a TRACERlab FX synthesis module for the automated production of gallium-68 radiopharmaceuticals using a cation-exchange cartridge for postprocessing of the Ge/ Ga generator eluate. The recovery of activity from the cartridge was 95.6% to 98.9% using solutions of acidified sodium chloride (5 M with pH = 1-3). The radiosyntheses of [ Ga]Ga-DOTANOC and [ Ga]Ga-PSMA-11 were performed using acetate sodium buffer or 4-(2-hydroxyethyl)piperazine-1-ethanesulfonic acid, with a total duration of 21 and 23 minutes, respectively, including generator elution and radiopharmaceutical dispensing. Activity yields were 77% ± 2% for [ Ga]Ga-PSMA-11 and 68% ± 3% for [ Ga]Ga-DOTANOC (n > 100). The labelled peptides had a radiochemical purity exceeding 97%, and all quality control parameters were in conformity with the limits prescribed by the European Pharmacopoeia.
全球对镓 - 68标记的正电子发射断层扫描探针的兴趣持续增长。然而,常规临床应用的障碍之一是相对简单标记程序的自动化合成单元的成本。在此,我们描述了TRACERlab FX合成模块的改造,用于使用阳离子交换柱对锗/镓发生器洗脱液进行后处理,以自动化生产镓 - 68放射性药物。使用酸化氯化钠溶液(5 M,pH = 1 - 3)时,柱的活度回收率为95.6%至98.9%。使用醋酸钠缓冲液或4 -(2 - 羟乙基)哌嗪 - 1 - 乙磺酸进行了[⁶⁸Ga]Ga - DOTANOC和[⁶⁸Ga]Ga - PSMA - 11的放射性合成,总时长分别为21分钟和23分钟,包括发生器洗脱和放射性药物分装。[⁶⁸Ga]Ga - PSMA - 11的活度产率为77%±2%,[⁶⁸Ga]Ga - DOTANOC的活度产率为68%±3%(n > 100)。标记肽的放射化学纯度超过97%,所有质量控制参数均符合欧洲药典规定的限度。