Cooper Lyndon F, Reside Glenn, Stanford Clark, Barwacz Chris, Feine Jocelyne, Nader Samer Abi, Scheyer Todd, McGuire Michael
Int J Oral Maxillofac Implants. 2019 Jan/Feb;34(1):150-158. doi: 10.11607/jomi.6810.
The goal of this investigation was to define time-dependent peri-implant tissue changes at implants with different abutment interface designs.
Participants requiring replacement of single maxillary anterior and first premolar teeth were recruited and treated under an institutional review board (IRB)-approved protocol. Implants, titanium abutments, and provisional crowns were placed in healed ridges 5 months following preservation after tooth extraction with recombinant human bone morphogenetic protein-2 (rhBMP-2). Twelve weeks later, permanent crowns were placed on patient-specific abutments and evaluated at 6, 12, and 36 months following implant placement. Clinical and radiographic assessments of abutments and crowns, peri-implant mucosa, and marginal bone levels were recorded.
The 3-year assessment included 45 conical interface (CI), 34 flat-to-flat interface (FI), and 32 platform-switched interface (PS) implants in 111 participants. At 3 years, the mean marginal bone level (MBL) change at CI, FI, and PS implants was -0.12, -1.02, and -1.04 mm, respectively (P = .014). "Zero" MBL loss or gain was measured over the 3-year period at 72.1% CI, 3.0% FI, and 16.6% PS implants. There was a minor change (0.0 to 0.3 mm) in peri-implant mucosal zenith positions over time and between groups. Eighty percent of CI implants, 61% of FI implants, and 84% of PS implants were observed to have a clinically stable peri-implant mucosal zenith position with less than 0.5 mm of measured recession. Over the 36-month period, there were no significant changes in the location of mesial or distal papilla in any group.
Significant differences in MBLs were observed at different implant interfaces. Conical implant interfaces, but not flat-to-flat or platform-switched implant interfaces, were associated with no MBL changes over 3 years. Peri-implant mucosal stability was generally observed. The relationship of marginal bone responses and peri-implant mucosal stability requires further evaluation.
本研究的目的是确定不同基台界面设计的种植体周围组织随时间的变化情况。
招募需要替换单颗上颌前牙和第一前磨牙的参与者,并在机构审查委员会(IRB)批准的方案下进行治疗。在拔牙后用重组人骨形态发生蛋白-2(rhBMP-2)保存5个月后的愈合牙槽嵴中植入种植体、钛基台和临时冠。12周后,在患者特异性基台上放置永久冠,并在种植体植入后6、12和36个月进行评估。记录基台和冠、种植体周围黏膜以及边缘骨水平的临床和影像学评估结果。
3年评估纳入了111名参与者的45颗锥形界面(CI)种植体、34颗平面到平面界面(FI)种植体和32颗平台转换界面(PS)种植体。3年后,CI、FI和PS种植体的平均边缘骨水平(MBL)变化分别为-0.12、-1.02和-1.04mm(P = 0.014)。在3年期间,72.1%的CI种植体、3.0%的FI种植体和16.6%的PS种植体测量到“零”MBL丢失或增加。种植体周围黏膜顶点位置随时间和组间有微小变化(0.0至0.3mm)。观察到80%的CI种植体、61%的FI种植体和84%的PS种植体具有临床稳定的种植体周围黏膜顶点位置,测量的退缩小于0.5mm。在36个月期间,任何组中近中或远中乳头的位置均无显著变化。
在不同种植体界面观察到MBL存在显著差异。锥形种植体界面,而非平面到平面或平台转换种植体界面,与3年内MBL无变化相关。一般观察到种植体周围黏膜稳定性。边缘骨反应与种植体周围黏膜稳定性的关系需要进一步评估。