The integrity of the coronoid process is critical to maintaining elbow stability. Unreconstructible fractures and chronic coronoid deficiency are challenging clinical problems with no clear solution. The purposes of this study were to investigate the shape match of the ipsilateral and contralateral olecranon tips as graft options and to determine the influence of the osteotomy angle on fitment.
Nineteen paired cadaveric elbow joints were investigated by 3-dimensional digital analysis of computed tomography DICOM (Digital Imaging and Communications in Medicine) data. After construction of an ulnar coordinate system, the ipsilateral and contralateral olecranon tips were digitally harvested at 10°, 20°, 30°, 40°, 50°, and 60° osteotomy angles. In an overlay analysis, we compared the shape match of the ipsilateral and contralateral grafts and the different angles.
The ipsilateral grafts showed an average mismatch of 1.8 mm (standard deviation, 1.38 mm), whereas the contralateral grafts had a significantly lower (P < .001) mean mismatch of 1.3 mm (standard deviation, 0.95 mm). The 50° osteotomy plane showed the best shape match in comparison with the native coronoid-in both the ipsilateral and contralateral grafts. Evaluation of the intraclass correlation coefficient was calculated at r = 0.944, showing high repeatability of the measurements.
The contralateral olecranon tip graft showed significantly better shape matching to the native coronoid than the ipsilateral olecranon graft. Specifically, the contralateral graft more closely matched the biomechanically critical anteromedial coronoid facet. Finally, both the contralateral and ipsilateral olecranon grafts had better shape matching with the native coronoid when osteotomy was performed at higher angles, specifically 50°.
喙突的完整性对于维持肘关节的稳定性至关重要。不可重建的骨折和慢性喙突缺失是具有挑战性的临床问题,目前尚无明确的解决方案。本研究的目的是研究同侧和对侧尺骨鹰嘴尖端的形状匹配作为移植物选择,并确定截骨角度对适配的影响。
通过对 19 对尸体肘部的三维数字分析,使用 CT DICOM(数字成像和通信医学)数据进行研究。构建尺骨坐标系后,在 10°、20°、30°、40°、50°和 60°截骨角度下,对同侧和对侧鹰嘴尖端进行数字采集。在叠加分析中,我们比较了同侧和对侧移植物的形状匹配以及不同角度的情况。
同侧移植物的平均不匹配度为 1.8mm(标准差 1.38mm),而对侧移植物的平均不匹配度明显较低(P<.001),为 1.3mm(标准差 0.95mm)。与原始喙突相比,50°截骨面在同侧和对侧移植物中均具有最佳的形状匹配。通过计算组内相关系数,评估结果为 r=0.944,表明测量具有高度可重复性。
与同侧鹰嘴尖端移植物相比,对侧鹰嘴尖端移植物与原始喙突的形状匹配明显更好。具体而言,对侧移植物更接近生物力学关键的前内侧喙突面。最后,当截骨角度较高时,同侧和对侧鹰嘴尖端移植物与原始喙突的形状匹配更好,特别是 50°。