Suppr超能文献

一种用于肾血管性高血压的新型准确且无创的筛查方法:肾动脉多普勒技术。

A new accurate and non-invasive screening method for renovascular hypertension: the renal artery Doppler technique.

作者信息

Handa N, Fukanaga R, Ogawa S, Matsumoto M, Kimura K, Kamada T

机构信息

First Department of Internal Medicine, Osaka University Medical School, Japan.

出版信息

J Hypertens Suppl. 1988 Dec;6(4):S458-60. doi: 10.1097/00004872-198812040-00144.

Abstract

The clinical use of ultrasonic echo Doppler velocimetry as a screening test for renal artery stenosis was investigated in 11 control subjects and 20 hypertensive patients including 10 with renovascular disease. In these hypertensive patients, the accuracy of the diagnosis of renal artery stenosis using the echo Doppler method was compared with that of angiography. The accuracy of the radionuclide renography in the same subjects was also investigated and compared with that of the echo Doppler method. Seven patients with renovascular disease who required angioplasty were examined again after the operation. The duplex Doppler signals were detected through the muscle of the back (the translumbar approach). Diagnosis of renal artery stenosis was based on three objectively defined Doppler parameters, the acceleration index, the acceleration time, and the acceleration:time ratio. In comparison with angiography, the accuracy of the echo Doppler method evaluated by using these parameters was 95%; the sensitivity was 100% and the specificity was 93%. The accuracy of the ultrasonic study was superior to that of radionuclide renography (80%). The acceleration index of the affected side was significantly correlated with the percentage stenosis of the renal artery. The changes in renal arterial blood flow following the operation were detected well by the Doppler parameters. This non-invasive method is one of the most accurate screening tests available for renovascular hypertension and has also proved quite useful for follow-up examinations in the patients with angioplasty.

摘要

对11名对照受试者和20名高血压患者(包括10名患有肾血管疾病的患者)进行了超声回波多普勒测速作为肾动脉狭窄筛查试验的临床应用研究。在这些高血压患者中,将使用回波多普勒方法诊断肾动脉狭窄的准确性与血管造影的准确性进行了比较。还对同一受试者的放射性核素肾图的准确性进行了研究,并与回波多普勒方法的准确性进行了比较。对7名需要进行血管成形术的肾血管疾病患者在术后再次进行了检查。通过背部肌肉(经腰途径)检测双功多普勒信号。肾动脉狭窄的诊断基于三个客观定义的多普勒参数,即加速指数、加速时间和加速时间比。与血管造影相比,使用这些参数评估的回波多普勒方法的准确性为95%;敏感性为100%,特异性为93%。超声检查的准确性优于放射性核素肾图(80%)。患侧的加速指数与肾动脉狭窄百分比显著相关。通过多普勒参数可以很好地检测到术后肾动脉血流的变化。这种非侵入性方法是可用于肾血管性高血压的最准确的筛查试验之一,并且已证明对血管成形术患者的随访检查也非常有用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验