• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Measuring leg length and leg length difference with the method of real time sonography].

作者信息

Holst A, Thomas W

机构信息

Allgemeines Krankenhaus Barmbek, Hamburg, I. Orthopädische Abteilung.

出版信息

Sportverletz Sportschaden. 1988 Jun;2(2):55-60. doi: 10.1055/s-2007-993667.

DOI:10.1055/s-2007-993667
PMID:3071879
Abstract

A brief presentation of the clinical and radiological methods to measure the leg length and the leg length difference is followed by an outline of the new diagnostic method for measuring the leg length and the leg length difference by means of real-time sonography. Tests conducted on corpses, as well as clinical examples, show that sonography is an ideal method for determining the exact lengths of the femur and tibia. The joint gaps on the hip joint, knee joint and upper ankle joint can be visualised by means of a 5 MHz linear scanner. A 1 mm strong metal bar on the skin and under the scanner are positioned at a right angle to the longitudinal axis of the body so that the bar can be seen in the centre of each joint gap by means of real-time sonography. A measuring device gives the distances of the joint gaps in cm so that the differences correspond to the real length of femur and tibia. This standardised measuring procedure is done by a specially developed bearing and measuring device. The results of the sonographical measurings on 20 corpses and checking after consecutive dissections showed in 75% of the cases a 100% sonographic measuring accuracy of the total leg length. The separately considered results for femur (85%) and tibia (90%) were even better. The maximum sonographic measuring fault was 1.0 cm for the femur (in one case) and 0.5 cm for the tibia, respectively. Thus, sonographic measuring of the leg length offers a reliable, non-invasive and easily performed new method that can be repeated any number of times. It is ideal for the development control of therapeutically influenced as well as spontaneous transformations of leg length differences.

摘要

相似文献

1
[Measuring leg length and leg length difference with the method of real time sonography].
Sportverletz Sportschaden. 1988 Jun;2(2):55-60. doi: 10.1055/s-2007-993667.
2
[Sonographic leg length measurement].
Rontgenblatter. 1989 Mar;42(3):134-8.
3
[A new procedure for determining leg length and leg length inequality using ultrasound. II: Comparison of ultrasound, teleradiography and 2 clinical procedures in 50 patients].[一种使用超声测定腿长及腿长不等的新方法。II:50例患者中超声、远程放射成像及两种临床方法的比较]
Unfallchirurg. 1996 Jan;99(1):43-51.
4
[Ultrasonographic measurement of leg length and leg length differences].
Z Orthop Ihre Grenzgeb. 1995 Sep-Oct;133(5):442-52. doi: 10.1055/s-2008-1039952.
5
[Ultrasound determination of leg length].
Orthopade. 2002 Mar;31(3):300-5. doi: 10.1007/s00132-001-0298-1.
6
[Intraoperative assessment of leg length in alloplastic hip joint replacement].
Z Orthop Ihre Grenzgeb. 1995 Sep-Oct;133(5):453-5. doi: 10.1055/s-2008-1039953.
7
[A new procedure for determination of leg length and differences in leg length using sonography. I. Development and experimental studies].[一种使用超声检查测定腿长及腿长差异的新方法。I. 方法开发与实验研究]
Unfallchirurg. 1994 Feb;97(2):98-106.
8
Joint moments in minor limb length discrepancy: a pilot study.下肢长度轻度差异中的关节力矩:一项初步研究。
Am J Orthop (Belle Mead NJ). 1997 Dec;26(12):852-6.
9
[Osteotomies in malalignments of the lower extremities].
Chirurg. 2002 Oct;73(10):982-9. doi: 10.1007/s00104-002-0542-1.
10
The relationship between the rotation possibilities between femur and tibia and the lengths of the cruciate ligaments.
J Theor Biol. 1993 Mar 21;161(2):199-220. doi: 10.1006/jtbi.1993.1050.

引用本文的文献

1
Length and angle measurements of the lower extremity in digital composite overview images.
Eur Radiol. 2005 Jan;15(1):158-64. doi: 10.1007/s00330-004-2352-y. Epub 2004 May 26.