Pediatric Intensive Care Unit, Burgos University Hospital, Avenida Islas Baleares s/n, CP 09006, Burgos, Spain.
Department of Neonatology, Burgos University Hospital, Burgos, Spain.
J Clin Monit Comput. 2019 Oct;33(5):749-755. doi: 10.1007/s10877-019-00268-1. Epub 2019 Feb 5.
To compare the newborn infant parasympathetic evaluation system (NIPE) scores with a validated clinical scale using two different nebulizers in children with bronchiolitis admitted to a PICU. Comfort was evaluated using the COMFORT-behavior scale (CBS) before (T1), during (T2) and after (T3) each nebulization. In order to compare NIPE and CBS values during the whole T1 to T3 period, the variable Dif-CBS was defined as the difference between maximal and minimal CBS scores, and Dif-NIPE as the difference between 75th and 25th percentile NIPE values. Analyses were carried out, firstly for the total of nebulizations and secondly comparing two different nebulization systems: a jet nebulizer (JN) and a nebulizer integrated in high flow nasal cannulas (NHF). 84 nebulizations were recorded on 14 patients with a median [25th-75th percentile] age of 6 months (3.1-9.5). A Dif-CBS of 4 points (2-7), as well as changes in CBS scores between T1 and T2, defined the nebulization as a discomfort stimulus. The NIPE system, represented as the Dif-NIPE, showed a median variation of 9 points (7-10), and was poorly correlated to Dif-CBS [r 0.162 (P = 0.142)]. Discomfort during nebulization, assessed by CBS was greater with the JN system compared to NHF: 17 (13-22) vs 13 (9-15) (P = 0.001). NIPE monitoring detected no significant differences between both nebulization systems (P = 0.706). NIPE monitoring showed a variation in comfort during nebulization in the patient with bronchiolitis, though correlation with CBS was poor. Further research is required before NIPE can be suggested as a comfort monitoring system for the awake infant.
比较新生儿副交感神经评估系统(NIPE)评分与使用两种不同雾化器在小儿重症监护病房(PICU)接受毛细支气管炎治疗的儿童中经过验证的临床量表。使用 COMFORT 行为量表(CBS)在每次雾化前(T1)、期间(T2)和之后(T3)评估舒适度。为了比较整个 T1 到 T3 期间的 NIPE 和 CBS 值,定义 Dif-CBS 变量为 CBS 评分的最大值和最小值之间的差异,Dif-NIPE 为 NIPE 值的第 75 百分位数和第 25 百分位数之间的差异。进行了分析,首先是对所有雾化的分析,其次是比较两种不同的雾化系统:射流雾化器(JN)和集成在高流量鼻插管中的雾化器(NHF)。对 14 名患者的 84 次雾化进行了记录,中位年龄为 6 个月(3.1-9.5)。CBS 评分在 T1 和 T2 之间的差值为 4 分(2-7),定义为雾化刺激。NIPE 系统,表现为 Dif-NIPE,中位数变化为 9 分(7-10),与 Dif-CBS 相关性差[r0.162(P=0.142)]。使用 CBS 评估的雾化期间的不适,使用 JN 系统比 NHF 系统更大:17(13-22)比 13(9-15)(P=0.001)。NIPE 监测未发现两种雾化系统之间存在显著差异(P=0.706)。NIPE 监测显示,毛细支气管炎患儿在雾化期间的舒适度存在变化,但与 CBS 的相关性较差。在建议 NIPE 作为清醒婴儿的舒适度监测系统之前,需要进行进一步的研究。