Prior B A, Casaleggio C, VAN Vuuren H J J
Department of Microbiology, University of the Orange Free State, P.O. Box 339, Bloemfontein, South Africa, 9300.
J Food Prot. 1977 Aug;40(8):537-539. doi: 10.4315/0362-028X-40.8.537.
A method is described to measure the water activity (a) of foods in the range of 0.935 to 1.0 using a psychrometer. Samples (0.15 to 0.35 g) were equilibrated for 2 h in the sample chamber before cooling the thermocouple and recording the subsequent voltage on the instrument. The a was read off a standard curve prepared from sodium chloride solutions of known water activity values. Results show that the method was considerably better than the graphical interpolation method and comparable to the microcrystalline method but was much quicker and required less effort.
描述了一种使用干湿球湿度计测量水分活度(a)在0.935至1.0范围内的食品的方法。将样品(0.15至0.35 g)在样品室中平衡2小时,然后冷却热电偶并记录仪器上随后的电压。水分活度从由已知水分活度值的氯化钠溶液制备的标准曲线上读出。结果表明,该方法比图解插值法好得多,与微晶法相当,但速度快得多且所需工作量少。