Ahn H C, Ekroth R, Hedenmark J, Nilsson G E, Svedjeholm R
Department of Thoracic and Cardiovascular Surgery, University Hospital, Uppsala, Sweden.
Cardiovasc Res. 1988 Oct;22(10):719-25. doi: 10.1093/cvr/22.10.719.
Laser Doppler flowmetry was applied to the empty beating heart of six pigs. Cardiopulmonary bypass was instituted and the preparation allowed continuous and simultaneous measurement of coronary sinus blood flow and local tissue perfusion. An epicardial and an intramuscular probe were used. Significant linear correlation coefficients were obtained between changes of laser Doppler signal and coronary sinus blood flow changes in all seven experiments in four animals (r from 0.71 to 0.94, p less than 0.005) and between laser Doppler signal and changes of extracorporeal bypass in five out of six experiments in four animals (r from 0.82 to 0.99, p less than 0.001). The correlation between coronary sinus flow and bypass flow of four pigs was significant (r from 0.81 to 0.98, p less than 0.001), the coronary flow being about 10% of bypass flow. Muscular activity of the heart contributed to the laser Doppler signal, the magnitude of this "noise level" varying between different experiments even in the same animal. A key question for the applicability of laser Doppler flowmetry to the beating heart is whether it will become possible to discriminate between flow and muscular contribution to the laser Doppler output.
激光多普勒血流仪应用于6只猪的空跳心脏。建立体外循环后,该装置可连续同步测量冠状窦血流量和局部组织灌注。使用了一个心外膜探头和一个肌内探头。在4只动物的所有7次实验中,激光多普勒信号变化与冠状窦血流量变化之间获得了显著的线性相关系数(r为0.71至0.94,p小于0.005);在4只动物的6次实验中的5次实验中,激光多普勒信号与体外循环变化之间也获得了显著的线性相关系数(r为0.82至0.99,p小于0.001)。4只猪的冠状窦血流量与旁路血流量之间的相关性显著(r为0.81至0.98,p小于0.001),冠状血流量约为旁路血流量的10%。心脏的肌肉活动对激光多普勒信号有贡献,即使在同一动物的不同实验中,这种“噪声水平”的大小也有所不同。激光多普勒血流仪应用于跳动心脏的一个关键问题是,是否有可能区分血流和肌肉活动对激光多普勒输出的贡献。