Suppr超能文献

开发并验证一种基于 F-氟脱氧葡萄糖正电子发射断层扫描与计算机断层扫描的工具,用于评估类风湿关节炎患者的关节计数和疾病活动度。

Development and Validation of an F-Fluorodeoxyglucose-Positron Emission Tomography With Computed Tomography-Based Tool for the Evaluation of Joint Counts and Disease Activity in Patients With Rheumatoid Arthritis.

机构信息

Kyungpook National University Hospital and Kyungpook National University, Daegu, Republic of Korea.

Kyungpook National University Hospital, Daegu, Republic of Korea.

出版信息

Arthritis Rheumatol. 2019 Aug;71(8):1232-1240. doi: 10.1002/art.40860. Epub 2019 Jun 17.

Abstract

OBJECTIVE

Clinical joint count assessment is important for detecting synovitis but its reliability is a subject of controversy. This study was undertaken to assess the correlation of positron emission tomography (PET)-derived parameters in 68 joints with disease activity and to compare the reliability of joint counts between PET with computed tomography (CT) and clinical assessment in patients with rheumatoid arthritis (RA).

METHODS

We enrolled 91 patients with active RA (69 in a development group and 22 in a validation group) who underwent concurrent F-fluorodeoxyglucose ( F-FDG)-PET-CT and clinical disease activity evaluation. PET-derived parameters were compared with disease activity assessed using clinical joint count parameters. A Disease Activity Score (DAS) using counts of PET-positive joints was developed, and then validation studies were performed in an independent group.

RESULTS

The number of PET-positive joints (of 28 and 68 joints) was significantly correlated with the swollen joint count (SJC) and tender joint count (TJC) and the DAS in 28 joints using the erythrocyte sedimentation rate (DAS28-ESR). Intraobserver and interobserver reliability of PET for the affected joint counts were excellent. Interobserver reliability between nuclear medicine physicians and rheumatologists was good for the SJC and TJC in both 28 joints and 68 joints. After multivariate analyses, including ESR and patient's global assessment of disease activity (PtGA) in addition to PET-derived parameters, the PET/DAS was derived as (0.063 × number of PET-positive joints in 28 joints) + (0.011 × ESR) + (0.030 × PtGA). A significant correlation between the PET/DAS and the DAS28-ESR was confirmed in the validation group (P < 0.001).

CONCLUSION

PET-CT could serve as a sensitive and reliable method in the evaluation of disease activity in RA patients, and may be applicable as a research tool, particularly in clinical trials.

摘要

目的

临床关节计数评估对于检测滑膜炎很重要,但其实用性存在争议。本研究旨在评估 68 个关节的正电子发射断层扫描(PET)衍生参数与疾病活动的相关性,并比较 PET 与计算机断层扫描(CT)和临床评估在类风湿关节炎(RA)患者中关节计数的可靠性。

方法

我们招募了 91 名活动性 RA 患者(69 名在开发组,22 名在验证组),他们同时接受了 F-氟脱氧葡萄糖( F-FDG)-PET-CT 和临床疾病活动评估。将 PET 衍生参数与使用临床关节计数参数评估的疾病活动进行比较。开发了一种基于 PET 阳性关节计数的疾病活动评分(DAS),然后在独立组中进行了验证研究。

结果

28 个和 68 个关节的 PET 阳性关节数与肿胀关节计数(SJC)和压痛关节计数(TJC)以及红细胞沉降率(DAS28-ESR)的 28 个关节 DAS 显著相关。核医学医师和风湿病学家对 PET 受累关节计数的观察者内和观察者间可靠性均极佳。28 个关节和 68 个关节的 SJC 和 TJC,核医学医师和风湿病学家之间的观察者间可靠性良好。在包括 ESR 和患者对疾病活动的整体评估(PtGA)以及 PET 衍生参数在内的多变量分析后,得出 PET/DAS 为(28 个关节中 PET 阳性关节数的 0.063)+(0.011×ESR)+(0.030×PtGA)。在验证组中,证实了 PET/DAS 与 DAS28-ESR 之间的显著相关性(P<0.001)。

结论

PET-CT 可作为评估 RA 患者疾病活动的一种敏感可靠的方法,可作为一种研究工具,特别是在临床试验中。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验