油的水载部分(WAF)和化学强化水载部分(CEWAF)的估计油当量(EOE)浓度的实验室间校准。

Inter-laboratory calibration of estimated oil equivalent (EOE) concentrations of a water accommodated fraction (WAF) of oil and a chemically enhanced WAF (CEWAF).

作者信息

Bera Gopal, Gold-Bouchot Gerardo, Passow Uta, Wade Terry L, Shi Dawei, Morales-McDevitt Maya, Ramirez-Miss Noemi, Knap Anthony H, Quigg Antonietta

机构信息

Geochemical and Environmental Research Group, Texas A&M University, College Station, Texas, USA.

Memorial University, St John's, Canada.

出版信息

Heliyon. 2019 Jan 29;5(1):e01174. doi: 10.1016/j.heliyon.2019.e01174. eCollection 2019 Jan.

Abstract

Chemical characterization of the presence of oil in environmental samples are performed using methods of varying complexity. Extraction of samples with an organic solvent and analysis by fluorescence spectrometry has been shown to be a rapid and effective screening technique for petroleum in the environment. During experiments, rapid analysis of oil by fluorescence provides the opportunity for researchers to modify the experimental conditions in real time. Estimated Oil Equivalents (EOE) relies on the fluorescence measurement of the aromatic compounds to estimate the oil concentration. The present intercalibration study was designed to investigate whether different fluorometer instruments can reliably measure EOE and whether the results are intercomparable. Additionally, the need for extraction of oil compounds into an organic solvent was investigated. Three different fluorometers were used in three different laboratories: a Horiba Aqualog, a Turner Trilogy and a Shimadzu Spectrofluorophotometer RF-1501. Results from these different instruments showed excellent agreement for EOE determinations. A very high correlation was found between the EOE results obtained with Aqualog Horiba and Turner Trilogy (r = 0.9999), with no significant differences between the mean EOE results (t-test, p = 0.30), and the Aqualog Horiba and Shimadzu (r = 0.995) fluorometers, with no statistically difference between the EOE results obtained by the two instruments (p = 0.40).

摘要

使用复杂度各异的方法对环境样品中的石油存在情况进行化学表征。用有机溶剂萃取样品并通过荧光光谱法进行分析,已被证明是一种用于环境中石油的快速有效筛选技术。在实验过程中,通过荧光对石油进行快速分析,为研究人员提供了实时修改实验条件的机会。估计油当量(EOE)依靠对芳香族化合物的荧光测量来估计油浓度。本次相互校准研究旨在调查不同的荧光计仪器能否可靠地测量EOE以及结果是否具有可比性。此外,还研究了将油化合物萃取到有机溶剂中的必要性。在三个不同实验室使用了三种不同的荧光计:一台堀场Aqualog、一台特纳Trilogy和一台岛津分光荧光光度计RF - 1501。这些不同仪器的结果在EOE测定方面显示出极佳的一致性。堀场Aqualog和特纳Trilogy获得的EOE结果之间发现了非常高的相关性(r = 0.9999),平均EOE结果之间无显著差异(t检验,p = 0.30),堀场Aqualog和岛津荧光计之间(r = 0.995),两种仪器获得的EOE结果之间无统计学差异(p = 0.40)。