Suppr超能文献

在社区药房使用基于IgA/IgG去酰胺化麦醇溶蛋白肽的即时检测法检测乳糜泻。

Coeliac disease detection with an IgA/IgG-deamidated gliadin peptide based point of care test in community pharmacies.

作者信息

Lau Michelle S, Sanders David S

机构信息

Academic Department of Gastroenterology, Room P18, Royal Hallamshire Hospital, Sheffield Teaching Hospitals, Sheffield, S10 2JF, UK.

出版信息

Int J Clin Pharm. 2019 Apr;41(2):583-588. doi: 10.1007/s11096-019-00793-8. Epub 2019 Feb 16.

Abstract

Background Coeliac disease affects 1% of the population, but 75% remain undiagnosed. Objective To conduct a case finding feasibility and efficacy study for the detection of coeliac disease in community pharmacies. Setting Six community pharmacies across Sheffield, UK. Method A prospective study was performed using a point of care test, Simtomax (IgA/IgG-deamidated gliadin peptide) (C-test) in pharmacies. Pharmacy customers with symptoms suggestive of or risk factors for coeliac disease were tested with the C-test. Positive individuals were referred for a gastroscopy with duodenal biopsies alongside conventional serology. People with known coeliac disease, those on a gluten free diet or those who were investigated for coeliac disease were excluded. Main outcome measure The case detection rate and the uptake rate of the C-test and gastroscopies. Results Five-hundred participants fulfilled the inclusion criteria and were tested with the C-test (369 females, 73.8%; age range 18-87, median 49). The C-test uptake rate was 63%, and the positive rate was 7.2% (36/500). Twenty-seven positive participants (75%) underwent further investigations, confirming three new cases of coeliac disease (0.6%). Conclusion It was feasible to use the C-test as a case finding tool in pharmacies. There was good uptake for the C-test, although the case detection rate and the test specificity were low. Based on this, the C-test has a limited role in case finding in a community pharmacy setting.

摘要

背景 乳糜泻影响1%的人口,但75%的患者仍未被诊断出来。目的 开展一项在社区药房检测乳糜泻的病例发现可行性和有效性研究。地点 英国谢菲尔德的六家社区药房。方法 在药房中使用即时检验试剂Simtomax(IgA/IgG-去酰胺化麦醇溶蛋白肽)(C检测)进行前瞻性研究。对有乳糜泻症状或风险因素的药房顾客进行C检测。检测结果呈阳性的个体被转诊进行十二指肠活检胃镜检查并同时进行传统血清学检测。已知患有乳糜泻的人、采用无麸质饮食的人或接受过乳糜泻检查的人被排除在外。主要观察指标 C检测、胃镜检查的病例检出率和接受率。结果 500名参与者符合纳入标准并接受了C检测(369名女性,占73.8%;年龄范围18 - 87岁,中位数为

相似文献

3
Simtomax, a novel point of care test for coeliac disease.Simtomax,一种用于乳糜泻的新型即时检验方法。
Expert Opin Med Diagn. 2013 Nov;7(6):645-51. doi: 10.1517/17530059.2013.836179. Epub 2013 Sep 24.

本文引用的文献

1
Global Prevalence of Celiac Disease: Systematic Review and Meta-analysis.全球乳糜泻患病率:系统评价和荟萃分析。
Clin Gastroenterol Hepatol. 2018 Jun;16(6):823-836.e2. doi: 10.1016/j.cgh.2017.06.037. Epub 2018 Mar 16.
5
Celiac disease.乳糜泻
J Allergy Clin Immunol. 2015 May;135(5):1099-106; quiz 1107. doi: 10.1016/j.jaci.2015.01.044.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验