• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Ultrasound detection of micro-emboli in the middle cerebral artery during cardiopulmonary bypass surgery.

作者信息

Deverall P B, Padayachee T S, Parsons S, Theobold R, Battistessa S A

机构信息

Department of Cardiothoracic Surgery, Guy's Hospital, London, UK.

出版信息

Eur J Cardiothorac Surg. 1988;2(4):256-60. doi: 10.1016/1010-7940(88)90080-2.

DOI:10.1016/1010-7940(88)90080-2
PMID:3078422
Abstract

The occurrence of neurological sequelae following cardiopulmonary bypass (CBP) surgery has stimulated interest in refining the techniques of extracorporeal circulation. Air micro-emboli originating from the oxygenator have been postulated as one source of cerebral damage. Since controversy still exists regarding the merits of bubble versus membrane oxygenators, this has prompted investigators to devise methods to determine the amount of micro-emboli produced during CPB. In this study, 27 patients undergoing CPB surgery for coronary artery disease (21) or valve replacement (6) were examined. The surgical and anaesthetic techniques were standardised in all patients except for the type of oxygenator used. A bubble oxygenator was used in 17 patients (Bentley Bio-10, William Harvey or Dideco) and a membrane oxygenator with a 25 microns filter in the remaining 10 patients (Bentley BOS CM50). Transcranial pulsed Doppler ultrasound was used to obtain blood velocity signals from the middle cerebral artery throughout CPB. A flow disturbance index (FDI) was defined which provided a representative index of the number of micro-emboli passing the ultrasound transducer. The FDI indicated the presence of gaseous micro-emboli during insertion of the aortic cannula in 22 of the 27 patients. In the 17 patients with a bubble oxygenator, the FDI ranged from 4-39. In the 10 patients with a membrane oxygenator, the FDI was always 0. Variation of gas flow rates in 3 patients with bubble oxygenators showed a change in the FDI from 4 +/- 4 at a flow rate of 2 l/min to 17 +/- 9 at 5 l/min.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
Ultrasound detection of micro-emboli in the middle cerebral artery during cardiopulmonary bypass surgery.
Eur J Cardiothorac Surg. 1988;2(4):256-60. doi: 10.1016/1010-7940(88)90080-2.
2
The detection of microemboli in the middle cerebral artery during cardiopulmonary bypass: a transcranial Doppler ultrasound investigation using membrane and bubble oxygenators.
Ann Thorac Surg. 1987 Sep;44(3):298-302. doi: 10.1016/s0003-4975(10)62077-2.
3
Significance of gaseous microemboli in the cerebral circulation during cardiopulmonary bypass in dogs.犬体外循环期间脑循环中气态微栓子的意义
Circulation. 1993 Nov;88(5 Pt 2):II319-29.
4
The effect of arterial filtration on reduction of gaseous microemboli in the middle cerebral artery during cardiopulmonary bypass.
Ann Thorac Surg. 1988 Jun;45(6):647-9. doi: 10.1016/s0003-4975(10)64768-6.
5
Oxygenation strategy and neurologic damage after deep hypothermic circulatory arrest. I. Gaseous microemboli.深低温停循环后的氧合策略与神经损伤。I. 气态微栓子
J Thorac Cardiovasc Surg. 1999 Jun;117(6):1166-71. doi: 10.1016/s0022-5223(99)70256-4.
6
Effect of Normobaric versus Hypobaric Oxygenation on Gaseous Microemboli Removal in a Diffusion Membrane Oxygenator: An In Vitro Comparison.常压与低压氧合对扩散膜式氧合器中气态微栓清除的影响:一项体外比较研究
J Extra Corpor Technol. 2016 Sep;48(3):129-136.
7
Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops.评估膜式氧合器和储血器捕获气态微栓和压降的能力。
Artif Organs. 2009 Nov;33(11):1037-43. doi: 10.1111/j.1525-1594.2009.00955.x. Epub 2009 Oct 28.
8
Generation, detection and prevention of gaseous microemboli during cardiopulmonary bypass procedure.体外循环过程中气态微栓子的产生、检测与预防
Int J Artif Organs. 2011 Nov;34(11):1039-51. doi: 10.5301/ijao.5000010.
9
A clinical evaluation of the gas transfer characteristics and gaseous microemboli production of two bubble oxygenators.
Life Support Syst. 1984 Oct-Dec;2(4):252-66.
10
Pulsatile flow decreases gaseous micro-bubble filtering properties of oxygenators without integrated arterial filters during cardiopulmonary bypass.在体外循环期间,搏动血流会降低没有集成动脉滤器的氧合器的气体微泡过滤性能。
Interact Cardiovasc Thorac Surg. 2013 Nov;17(5):811-7. doi: 10.1093/icvts/ivt264. Epub 2013 Jul 9.

引用本文的文献

1
Microembolic signal detection in acute ischemic stroke: Clinical relevance and impact on treatment individualization-A narrative review.急性缺血性卒中中的微栓塞信号检测:临床相关性及对治疗个体化的影响——一篇叙述性综述
Eur J Neurol. 2025 Jan;32(1):e16584. doi: 10.1111/ene.16584.
2
Single cell analyses reveal contrasting life strategies of the two main nitrifiers in the ocean.单细胞分析揭示了海洋中两种主要硝化菌的截然不同的生存策略。
Nat Commun. 2020 Feb 7;11(1):767. doi: 10.1038/s41467-020-14542-3.
3
Diversity and metabolism of Woeseiales bacteria, global members of marine sediment communities.
沃氏菌门细菌的多样性及其代谢作用,该类菌为海洋沉积物群落中的全球性成员。
ISME J. 2020 Apr;14(4):1042-1056. doi: 10.1038/s41396-020-0588-4. Epub 2020 Jan 27.
4
Microemboli in our bypass circuits: a contemporary audit.我们体外循环回路中的微栓子:一项当代审计。
J Extra Corpor Technol. 2009 Dec;41(4):P31-7.
5
Effects of myocardial contractility on microemboli production by mechanical heart valves in a bovine model.在牛模型中,心肌收缩力对机械心脏瓣膜产生微栓子的影响。
Tex Heart Inst J. 2000;27(3):236-9.
6
Monitoring during paediatric cardiac anaesthesia.小儿心脏麻醉期间的监测。
Can J Anaesth. 1994 Sep;41(9):818-44. doi: 10.1007/BF03011590.