Van Puyvelde Joeri, Rega Filip, Minami Tomoyuki, Claus Piet, Cools Bjorn, Gewillig Marc, Meyns Bart
Department of Cardiac Surgery, University Hospitals Leuven, Leuven, Belgium.
Department of Cardiovascular Imaging and Dynamics, University Hospitals Leuven, Leuven, Belgium.
Interact Cardiovasc Thorac Surg. 2019 Jul 1;29(1):15-21. doi: 10.1093/icvts/ivz022.
Patients with a single ventricle survive thanks to the Fontan palliation. Nevertheless, there is a growing number of Fontan patients with progressive heart failure. To validate therapeutic options in these patients, we developed a chronic Fontan large animal model.
A Fontan circulation was surgically created in 15 sheep. The superior vena cava was anastomosed end-to-side to the pulmonary artery. The inferior vena cava was connected to the pulmonary artery by an ePTFE conduit, and the inferior vena cava-right atrium junction was ligated.
Total cavopulmonary connection was successfully performed in all 15 animals. After creation of the Fontan circulation, central venous pressure increased from 4 [interquartile range (IQR) 3-6] mmHg to 16 (IQR 14-17) mmHg, mean arterial blood pressure decreased from 68 (IQR 54-75) mmHg to 52 (IQR 50-61) mmHg and cardiac output decreased from 5.1 (IQR 4.6-6.8) l/min to 1.7 (IQR 1.3-2.7) l/min. Five animals were electively sacrificed after a follow-up period of 21 weeks.
These results demonstrate that it is feasible to create a chronic animal model with unsupported Fontan circulation. This animal model not only opens perspectives to investigate the pathophysiology of the failing Fontan circulation, but also provides the possibility to study therapeutic options such as the effect of mechanical circulatory support in the failing Fontan physiology.
单心室患者因Fontan姑息手术得以存活。然而,患有进行性心力衰竭的Fontan患者数量正在不断增加。为了验证这些患者的治疗方案,我们建立了一种慢性Fontan大型动物模型。
对15只绵羊进行手术创建Fontan循环。上腔静脉与肺动脉行端侧吻合。下腔静脉通过膨体聚四氟乙烯(ePTFE)导管与肺动脉相连,并结扎下腔静脉-右心房交界处。
所有15只动物均成功完成全腔肺连接。创建Fontan循环后,中心静脉压从4[四分位间距(IQR)3 - 6]mmHg升至16(IQR 14 - 17)mmHg,平均动脉血压从68(IQR 54 - 75)mmHg降至52(IQR 50 - 61)mmHg,心输出量从5.1(IQR 4.6 - 6.8)升/分钟降至1.7(IQR 1.3 - 2.7)升/分钟。5只动物在随访21周后被选择性处死。
这些结果表明,建立无辅助Fontan循环的慢性动物模型是可行的。该动物模型不仅为研究衰竭Fontan循环的病理生理学开辟了前景,还为研究治疗方案提供了可能,如机械循环支持对衰竭Fontan生理学的影响。