Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Trojdena 4, 02-109, Warsaw, Poland.
I Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
Ann Biomed Eng. 2019 May;47(5):1300-1313. doi: 10.1007/s10439-019-02231-2. Epub 2019 Feb 21.
Standard 12-lead ECG exercise testing is commonly used for screening of ischemic heart disease (IHD). We studied if high-resolution body surface potential mapping (HR-BSPM) during exercise offers advantages over current standards in noninvasive evaluation of IHD. This study was carried out on 90 IHD patients and 33 healthy controls. The 67-lead HR-BSPM was recorded at rest and during exercise. Twenty-one ECG parameters including classical ST criteria were compared. The effectiveness of methods was verified based on the results of SPECT and coronary angiography. The most effective parameters in the diagnosis of IHD were: amplitude parameter ΔST60 and δT parameter showing T-wave morphology changes during exercise. The sensitivities/specificities of ΔST60 and δT parameters for the HR-BSPM were 70/69 and 59/62%, while for the standard 12-lead ECG system they were: 63/62 and 59/56%. These results demonstrate the usefulness of HR-BSPM measurements during exercise. HR-BSPM resulted in higher sensitivities and specificities compared to the standard 12-lead exercise test. The advantage was partially associated with observed ischemic changes outside standard precordial leads position that were not visible when using the standard 12-lead exercise test. This justifies research into the optimization of the number and position of ECG leads in exercise testing.
标准 12 导联心电图运动试验常用于筛查缺血性心脏病 (IHD)。我们研究了在 IHD 的无创评估中,运动时高分辨率体表电位图 (HR-BSPM) 是否优于当前标准。这项研究在 90 例 IHD 患者和 33 例健康对照者中进行。在休息和运动时记录 67 导联 HR-BSPM。比较了包括经典 ST 标准在内的 21 个心电图参数。根据 SPECT 和冠状动脉造影的结果验证了这些方法的有效性。在诊断 IHD 方面最有效的参数是:在运动过程中显示 T 波形态变化的幅度参数 ΔST60 和 δT 参数。HR-BSPM 中 ΔST60 和 δT 参数的敏感性/特异性分别为 70/69%和 59/62%,而标准 12 导联心电图系统的敏感性/特异性分别为 63/62%和 59/56%。这些结果表明运动时 HR-BSPM 测量的有用性。与标准 12 导联运动试验相比,HR-BSPM 的敏感性和特异性更高。这种优势部分与观察到的标准胸前导联位置以外的缺血性变化有关,而使用标准 12 导联运动试验时这些变化是不可见的。这证明了在运动试验中优化心电图导联的数量和位置的研究是合理的。