Suppr超能文献

一种极为罕见的并发症:Zenith 主体在修复肾上支架分离数年后迁移导致腹主动脉瘤破裂。

An Extremely Rare Complication: Abdominal Aortic Aneurysm Rupture Caused by Migration of a Zenith Main Body Years After Repair of the Suprarenal Stent Separation.

机构信息

1 Department of Radiology, Nippon Medical School Hospital, Tokyo, Japan.

2 Center for Minimally Invasive Treatment, Nippon Medical School Musashikosugi Hospital, Kanagawa, Japan.

出版信息

J Endovasc Ther. 2019 Apr;26(2):269-272. doi: 10.1177/1526602819830979. Epub 2019 Feb 25.

Abstract

PURPOSE

To report an unusual case of an abdominal aortic aneurysm (AAA) rupture caused by migration of a Zenith stent-graft main body years after its separation from the suprarenal stent.

CASE REPORT

A 72-year-old man underwent endovascular aneurysm repair with a Zenith stent-graft for an infrarenal AAA in year 2000. At that time, a femorofemoral bypass was performed because the left external iliac and common femoral arteries were dissected during treatment. In 2013, follow-up computed tomography (CT) showed disconnection of the uncovered proximal stent, which led to a type Ia endoleak. An additional Zenith main body and Large Palmaz XL balloon-expandable stent were deployed; the endoleak disappeared. In 2016, the patient had abdominal pain, and emergency CT showed AAA rupture caused by migration of the first main body deployed in 2000 under the distal edge of the contralateral (left) leg of the additional main body from 2013, which led to a type IIIa endoleak between the 2 main bodies. A converter and iliac legs were deployed to successfully seal the type IIIa endoleak. The patient remains well 18 months after the second repair; CT scans document stable stent-grafts and no endoleak.

CONCLUSION

Physicians should be aware of the potential risk for AAA rupture caused by late main body migration after treatment for suprarenal stent separation from a Zenith stent-graft.

摘要

目的

报告一例肾上型支架移植物脱离肾上支架多年后主干体迁移导致腹主动脉瘤(AAA)破裂的罕见病例。

病例报告

一名 72 岁男性于 2000 年因肾下型 AAA 行血管内动脉瘤修复术,使用 Zenith 支架移植物。当时因治疗过程中左髂外和股总动脉夹层而行股股旁路术。2013 年,随访 CT 显示未覆盖的近端支架断开,导致 Ia 型内漏。进一步植入 Zenith 主干和 Large Palmaz XL 球囊扩张支架,内漏消失。2016 年,患者出现腹痛,急诊 CT 显示 AAA 破裂,由 2000 年首次植入的主干在 2013 年附加主干的对侧(左)下肢远端迁移引起,导致两主干之间出现 IIIa 型内漏。植入转换和髂支成功封堵了 IIIa 型内漏。第二次修复后 18 个月患者情况良好;CT 扫描显示支架稳定,无内漏。

结论

对于 Zenith 支架移植物肾上型支架分离后的治疗,医生应意识到晚期主干体迁移导致 AAA 破裂的潜在风险。