Parambeth Joseph C, Lidbury Jonathan A, Suchodolski Jan S, Steiner Jörg M
Am J Vet Res. 2019 Mar;80(3):259-264. doi: 10.2460/ajvr.80.3.259.
OBJECTIVE To develop and validate a sandwich ELISA for the measurement of α-proteinase inhibitor (α-PI) concentrations in serum and fecal samples obtained from common marmosets (Callithrix jacchus). SAMPLE Leftover serum (n = 42) and fecal (23) samples submitted for diagnostic testing; paired serum and fecal samples obtained from 30 common marmosets at 2 research colonies. PROCEDURES A sandwich ELISA was developed and analytically validated by determining the lower limit of detection, linearity, accuracy, precision, and reproducibility. Reference intervals for α-PI concentrations in serum and feces of common marmosets were calculated. RESULTS The standard curve was generated for concentrations between 1 and 100 ng/mL. Mean ± SD observed-to-expected ratio for serial dilutions of serum and fecal samples was 117.1 ± 5.6% (range, 112.2% to 123.0%) and 106.1 ± 19.7% (range, 82.6% to 130.2%), respectively. Mean observed-to-expected ratio for spiking recovery of serum and fecal samples was 102.9 ± 12.1% (range, 86.8% to 115.8%) and 97.9 ± 19.0% (range, 83.0% to 125.1%), respectively. Reference interval for serum concentrations of α-PI was 1,254 to 1,813 μg/mL, for 3-day mean fecal concentrations was 11.5 to 42.2 μg/g of feces, and for 3-day maximum fecal concentrations was 13.2 to 51.2 μg/g of feces. CONCLUSIONS AND CLINICAL RELEVANCE The ELISA was linear, accurate, precise, and reproducible for quantification of α-PI concentrations in serum and feces of common marmosets. However, the ELISA had limited linearity and accuracy for spiking recovery of fecal samples.
目的 开发并验证一种夹心酶联免疫吸附测定法(ELISA),用于检测普通狨猴(Callithrix jacchus)血清和粪便样本中α-蛋白酶抑制剂(α-PI)的浓度。样本 提交用于诊断检测的剩余血清样本(n = 42)和粪便样本(23份);从2个研究群落的30只普通狨猴获取的配对血清和粪便样本。方法 开发一种夹心ELISA,并通过确定检测下限、线性、准确性、精密度和可重复性进行分析验证。计算普通狨猴血清和粪便中α-PI浓度的参考区间。结果 生成了浓度在1至100 ng/mL之间的标准曲线。血清和粪便样本系列稀释的平均观察值与预期值之比分别为117.1±5.6%(范围为112.2%至123.0%)和106.1±19.7%(范围为82.6%至130.2%)。血清和粪便样本加标回收率的平均观察值与预期值之比分别为102.9±12.1%(范围为86.8%至115.8%)和97.9±19.0%(范围为83.0%至125.1%)。α-PI血清浓度的参考区间为1254至1813 μg/mL,3天粪便平均浓度为11.5至42.2 μg/g粪便,3天粪便最大浓度为13.2至51.2 μg/g粪便。结论及临床意义 该ELISA法在定量普通狨猴血清和粪便中α-PI浓度方面具有线性、准确性、精密度和可重复性。然而,该ELISA法在粪便样本加标回收率方面的线性和准确性有限。