Phan Chau-Minh, Subbaraman Lakshman N, Jones Lyndon W
Centre for Ocular Research and Education (formerly Centre for Contact Lens Research), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada *
Optom Vis Sci. 2019 Mar;96(3):180-186. doi: 10.1097/OPX.0000000000001351.
Polyvinyl alcohol is a wetting agent that could reduce the symptoms of dry eye and contact lens discomfort. Currently, only one lens type, nelfilcon A (DAILIES AquaComfort Plus), releases polyvinyl alcohol. The concept of releasing this agent from contact lenses could be applied to other lens materials.
The purpose of this study was to measure the release of polyvinyl alcohol from commercially available hydrogel daily disposable contact lenses using refractive index and iodine-borate methods.
Etafilcon A, omafilcon A, and nelfilcon A were soaked in phosphate-buffered saline and 0.2% trifluoroacetic acid/acetonitile for 24 hours to remove residual blister pack components. The lenses were then incubated in a 10-mg/mL solution of polyvinyl alcohol for 24 hours. After the incubation period, the lenses were placed in 2 mL of phosphate-buffered saline. At specified time intervals, t = 0.5, 1, 2, 4, 8, 12, and 24 hours, the samples were evaluated using refractive index and an iodine-borate assay. Polyvinyl alcohol uptake was determined by extracting the lenses with methanol for 24 hours.
There were no differences in the uptake of polyvinyl alcohol between lens types (P > .05). The release of this wetting agent for all lens types followed a burst-plateau profile after the first 30 minutes (P > .05). Nelfilcon A had a slightly higher release of polyvinyl alcohol (P < .05) than did etafilcon A but was similar to omafilcon A (P > .05).
The results suggest that the contact lenses tested in this study have similar efficiency in delivering polyvinyl alcohol.
聚乙烯醇是一种湿润剂,可减轻干眼症状和隐形眼镜佩戴不适。目前,只有一种镜片类型(奈非那酮A,即DAILIES AquaComfort Plus)能释放聚乙烯醇。从隐形眼镜中释放这种药剂的概念可应用于其他镜片材料。
本研究的目的是使用折射率和碘硼酸盐法测量市售水凝胶日抛型隐形眼镜中聚乙烯醇的释放量。
将依他菲酮A、奥马菲酮A和奈非那酮A浸泡在磷酸盐缓冲盐溶液和0.2%三氟乙酸/乙腈中24小时,以去除泡罩包装中的残留成分。然后将镜片在10 mg/mL的聚乙烯醇溶液中孵育24小时。孵育期结束后,将镜片置于2 mL磷酸盐缓冲盐溶液中。在特定时间间隔(t = 0.5、1、2、4、8、12和24小时),使用折射率和碘硼酸盐测定法对样品进行评估。通过用甲醇提取镜片24小时来测定聚乙烯醇的摄取量。
不同镜片类型之间聚乙烯醇的摄取量没有差异(P > .05)。在最初30分钟后,所有镜片类型的这种湿润剂释放均呈现出突释-平台型特征(P > .05)。奈非那酮A的聚乙烯醇释放量略高于依他菲酮A(P < .05),但与奥马菲酮A相似(P > .05)。
结果表明,本研究中测试的隐形眼镜在递送聚乙烯醇方面具有相似的效率。