Suppr超能文献

Gunshot residue background on police officers: Considerations for secondary transfer in GSR evidence evaluation.

作者信息

Lucas Nick, Cook Michael, Kirkbride K Paul, Kobus Hilton

机构信息

College of Science and Engineering, Flinders University, Sturt Road, Bedford Park, South Australia, Australia.

Forensic Science SA, Divett Place, Adelaide, South Australia, Australia.

出版信息

Forensic Sci Int. 2019 Apr;297:293-301. doi: 10.1016/j.forsciint.2019.02.017. Epub 2019 Feb 21.

Abstract

In order to have confidence in the integrity of a GSR test result, it is essential to understand the factors that may influence the presence of GSR particles on a person of interest's hands beyond the discharge of a firearm. One important consideration is the possibility that a person of interest (POI) may become contaminated with GSR through their interactions with firearms-carrying police officers during the process of apprehension or arrest. This situation has the potential to result in a false positive error, and potentially result in the mistaken inclusion of a POI in an investigation. Prior studies have indicated that receiving a firearm at the start of shift represents a significant contamination event, which may result in GSR persisting on the hands of police officers (Cook, 2016). Firearms-carrying police officers were sampled at various points throughout their shift to ascertain the extent of persistence of GSR on their hands, as a potential population that could then be transferred. A secondary transfer study was also conducted, with several 'mock arrest' scenarios used as a means of modelling the extent and dynamics of any secondary GSR transfer. When compared to the random population, it was found that police exhibit GSR contamination of their hands at a higher frequency. 7.9% of the officers sampled in this study returned at least one, 3-component particle characteristic of GSR. Further, 75% of the officers tested had at least one particle considered consistent with GSR present on their hands. However, the overall particle numbers were relatively low, with the average reported number of characteristic particles being less than five, and the greatest number reported being twelve. When considering the possibility of secondary transfer occurring during the process of arrest, it was further determined through secondary transfer experiments that the most probable transfer situation was fewer than 25% of the particles present on an officer's hands would be transferred to a POI as a result of a short 'mock arrest' contact. We conclude that although the possibility of GSR contamination through the process of arrest exists, and is worthy of consideration in the assessment of GSR evidence, it is not an overwhelming, or major concern.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验