[Balloon catheter dilation of severe pulmonary restenosis 11 years after surgical valvulotomy].

作者信息

Berland J, Cribier A, Champoud O, Barbe P, Letac B

出版信息

Arch Mal Coeur Vaiss. 1986 Mar;79(3):385-9.

PMID:3087323
Abstract

A young girl who underwent repair of an atrial septal defect and pulmonary valvulotomy when 6 years of age, presented with clinical and haemodynamic signs of pulmonary restenosis 11 years later: right ventricular systolic pressure (RVSP) of 130 mmHg with a systolic RV/PA pressure gradient of 105 mmHg. Pulmonary valvuloplasty was performed using a balloon catheter (20 mm X 40 mm). Two inflations were necessary to correct the hour glass deformity of the balloon caused by the stenosis. After valvuloplasty the RVSP was 75 mmHg and the RV/PA gradient 55 mmHg. The calculated pulmonary valve surface area increased from 0.36 cm2 to 0.72 cm2. Angiography performed immediately after dilatation showed improved valvular mobility but here was persistant severe infundibular hypertrophy. The intensity of the pulmonary systolic murmur decreased. The good result obtained in this case shows that percutaneous valvuloplasty may be considered when restenosis occurs several years after surgical valvulotomy. Control catheterisation performed two months after dilatation confirmed the good initial haemodynamic result.