• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Numerical and experimental validation of a single-camera 3D velocimetry based on endoscopic tomography.

作者信息

Zhao Jianan, Liu Hecong, Cai Weiwei

出版信息

Appl Opt. 2019 Feb 20;58(6):1363-1373. doi: 10.1364/AO.58.001363.

DOI:10.1364/AO.58.001363
PMID:30874020
Abstract

Tomographic velocimetry as a 3D technique has attracted substantial research interests in recent years due to the pressing need for investigations of complex turbulent flows, which are inherently inhomogeneous. However, tomographic velocimetry usually suffers from high experimental costs, especially due to the formidable expenses of multiple high-speed cameras and the excitation laser source. To overcome this limitation, a cost-effective technique called endoscopic tomographic velocimetry has been developed in this work. As a single-camera system, nine projections of the target 3D luminous field at consecutive time instants can be registered from different orientations with one camera and customized fiber bundles, while this is possible only with the same number of cameras in a classical tomographic velocimetry system. Extensive numerical simulations were conducted with three inversion algorithms and two velocity calculation methods. According to RMS error analysis, it was found that the algebraic reconstruction technique outperformed the other two inversion algorithms, and the 3D optical flow method exhibited a better performance than cross correlation in terms of both accuracy and noise immunity. Proof-of-concept experiments were also performed to validate our developed system. The results suggested that an average reconstruction error of the artificially generated 3D velocity field was less than 6%, indicating good performance of the velocimetry system. Although this technique was demonstrated by reconstructing continuous luminous fields, it can be easily extended to discrete ones, which are typically adopted in particle image velocimetry. This technique is promising not only for flow diagnostics but other research areas such as biomedical imaging.

摘要

相似文献

1
Numerical and experimental validation of a single-camera 3D velocimetry based on endoscopic tomography.
Appl Opt. 2019 Feb 20;58(6):1363-1373. doi: 10.1364/AO.58.001363.
2
Assessment of plenoptic imaging for reconstruction of 3D discrete and continuous luminous fields.用于三维离散和连续光场重建的全光成像评估
J Opt Soc Am A Opt Image Sci Vis. 2019 Feb 1;36(2):149-158. doi: 10.1364/JOSAA.36.000149.
3
Mapping mean and fluctuating velocities by Bayesian multipoint MR velocity encoding-validation against 3D particle tracking velocimetry.通过贝叶斯多点磁共振速度编码绘制平均速度和脉动速度——与三维粒子跟踪测速法的对比验证
Magn Reson Med. 2014 Apr;71(4):1405-15. doi: 10.1002/mrm.24785. Epub 2013 May 13.
4
A three-dimensional strain measurement method in elastic transparent materials using tomographic particle image velocimetry.一种使用断层粒子图像测速技术的弹性透明材料三维应变测量方法。
PLoS One. 2017 Sep 14;12(9):e0184782. doi: 10.1371/journal.pone.0184782. eCollection 2017.
5
Multiple-plane particle image velocimetry using a light-field camera.使用光场相机的多平面粒子图像测速技术
Opt Express. 2013 Jan 28;21(2):1726-40. doi: 10.1364/OE.21.001726.
6
Systematic errors in optical-flow velocimetry for turbulent flows and flames.
Appl Opt. 2001 Feb 20;40(6):757-64. doi: 10.1364/ao.40.000757.
7
Note: development of a compact x-ray particle image velocimetry for measuring opaque flows. II. Three-dimensional velocity field reconstruction.注意:用于测量不透明流的紧凑型X射线粒子图像测速技术的发展。II. 三维速度场重建。
Rev Sci Instrum. 2012 Apr;83(4):046102. doi: 10.1063/1.3700811.
8
Smartphone-based particle tracking velocimetry for the in vitro assessment of coronary flows.基于智能手机的粒子跟踪测速法用于体外评估冠状动脉血流。
Med Eng Phys. 2024 Apr;126:104144. doi: 10.1016/j.medengphy.2024.104144. Epub 2024 Mar 11.
9
3D SAPIV particle field reconstruction method based on adaptive threshold.
Appl Opt. 2018 Mar 1;57(7):1622-1633. doi: 10.1364/AO.57.001622.
10
EndoAbS dataset: Endoscopic abdominal stereo image dataset for benchmarking 3D stereo reconstruction algorithms.EndoAbS数据集:用于3D立体重建算法基准测试的内窥镜腹部立体图像数据集。
Int J Med Robot. 2018 Oct;14(5):e1926. doi: 10.1002/rcs.1926. Epub 2018 Jul 3.

引用本文的文献

1
Quantitative Measurement of OH* and CH* Chemiluminescence in Jet Diffusion Flames.射流扩散火焰中OH*和CH*化学发光的定量测量
ACS Omega. 2020 Jun 25;5(26):15922-15930. doi: 10.1021/acsomega.0c01093. eCollection 2020 Jul 7.