Lasemi Esshagh, Motamedi Mohammad Hosein Kalantar, Talaeipour Ahmad Reza, Shafaeifard Shahrouz, Fard Mohamad Javad Kharrazi, Navi Fina, Lasemi Reza, Zardi Zahra, Alipanah Farhad
Department of Oral and Maxillofacial Surgery Associate Professor, Dental Branch, Islamic Azad University, Tehran, Iran.
Oral and Maxillofacial Surgery Professor, Trauma Research Center, Baqiyatallah University of Medical Sciences, Tehran and Islamic Azad University CMF Research Center, Tehran, Iran.
Anesth Prog. 2019 Spring;66(1):20-23. doi: 10.2344/anpr-65-04-05.
The location of the mandibular foramen (MF) on digital panoramic radiographs can be an important guide for clinicians when administering the inferior alveolar nerve block (IANB) for dental anesthesia of the mandible. This study, aimed to assess the location of the MF relative to the anterior border (AB) of the ramus and the occlusal plane (OP) from digital panoramic radiographs. An observational case series study was conducted on digital panoramic radiographs from the oral and maxillofacial radiology department archives of patients at least 18 years of age with a 1:1 scale (100%). The samples had to have at least 2 lower molar teeth on both sides without any blurring, previous fracture of the ramus or other artifacts. The distance of the MF to the OP and the AB of the ramus was measured using a caliper. The role of age and gender were also analyzed statistically using the 2-way analysis of variance test. One hundred ninety-four digital panoramic radiographs were included in the analysis. The findings showed that the vertical distance of the MF to the OP was a maximum of 14.52 mm and a minimum of -3.0 mm (mean 4.32 ± 2.34 mm). The distance of the MF to the AB of the ramus was a maximum of 25.52 and a minimum 9.68 mm (mean 16.48 ± 3.28 mm). Based on these findings, the IANB target site for injection should be approximately 5 mm above the OP and approximately 16.5 mm beyond the AB of the ramus to achieve successful anesthesia of the mandible via standard IANB in an Iranian population.
在下颌骨牙麻醉实施下牙槽神经阻滞(IANB)时,数字化全景X线片上下颌孔(MF)的位置对临床医生而言可能是一项重要的指导依据。本研究旨在通过数字化全景X线片评估MF相对于下颌支前缘(AB)和咬合平面(OP)的位置。对来自口腔颌面放射科档案中年龄至少18岁患者的数字化全景X线片进行了一项观察性病例系列研究,比例为1:1(100%)。样本两侧必须至少有2颗下颌磨牙,且无任何模糊、下颌支既往骨折或其他伪影。使用卡尺测量MF到OP以及下颌支AB的距离。还使用双向方差分析测试对年龄和性别的作用进行了统计学分析。194张数字化全景X线片纳入分析。结果显示,MF到OP的垂直距离最大为14.52 mm,最小为 -3.0 mm(平均4.32±2.34 mm)。MF到下颌支AB的距离最大为25.52 mm,最小为9.68 mm(平均16.48±3.28 mm)。基于这些结果,在伊朗人群中,通过标准IANB实现下颌骨成功麻醉时,IANB注射的目标部位应在OP上方约5 mm处且在下颌支AB后方约16.5 mm处。