Suppr超能文献

特发性室性早搏患者机电功能障碍的早期检测

Early detection of electromechanical dysfunction in patients with idiopathic premature ventricular contractions.

作者信息

Walia Rohit, Chang Shih-Lin, Lin Yenn-Jiang, Lo Li-Wei, Hu Yu Feng, Chao Tze-Fan, Chung Fa-Po, Liao Jo-Nan, Lin Chin-Yu, Chang Yao-Ting, Lin Chung-Hsing, Te Abigail Louise D, Yamada Shinya, Chen Shih-Ann, Tsao Hsuan-Ming

机构信息

Division of Cardiology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan.

Department of Medicine, National Yang-Ming University School of Medicine, Taipei, Taiwan.

出版信息

Pacing Clin Electrophysiol. 2019 Jun;42(6):637-645. doi: 10.1111/pace.13650. Epub 2019 Apr 17.

Abstract

BACKGROUND

Premature ventricular contractions (PVCs) induced by subtle cardiac dysfunction are missed by echocardiography. We evaluated acoustic cardiography for detection of early electromechanical dysfunction in patients with idiopathic PVCs and normal left ventricular ejection fraction (LVEF), and investigated the impact of radiofrequency ablation (RFA) in reversing this adverse effect.

METHODS

Eighty-six patients with PVCs and 33 normal controls having normal LVEF were studied. Fifty PVC patients were in the ablation group and 36 in the nonablation group. %Electromechanical activation time (%EMAT), %left ventricular systolic time (%LVST), third (S3) and fourth heart sound (S4), and systolic dysfunction index (SDI) during sinus rhythm (SR) were measured by acoustic cardiography (Audicor, Inovise Medical, Inc., Beaverton, OR, USA) pre- and postablation. In 28 patients, acoustic parameters were compared during SR without PVCs, and SR with single PVC, ≥ 2 PVCs, or ventricular tachycardia over 10-second Audicor recording in a single patient at different times. Twenty-four-hour acoustic cardiographic and acoustic cardiographic Holter recording were used to assess the impact of PVC burden on electromechanical function in 41 patients.

RESULTS

%EMAT, S3, S4, and SDI showed significant worsening in the PVC versus control group. %EMAT and SDI were worsened with increasing PVC number in a 10-second strip. %EMAT showed significant linear increment with increasing PVC burden. There was a significant improvement in %EMAT, %LVST, S3, S4, and SDI postablation in patients with PVCs.

CONCLUSION

Acoustic cardiography can detect PVC-induced minor electromechanical dysfunction in patients with normal LVEF. RFA can reverse this adverse effect.

摘要

背景

超声心动图会漏诊由细微心脏功能障碍引起的室性早搏(PVC)。我们评估了心音图在检测特发性PVC且左心室射血分数(LVEF)正常的患者早期机电功能障碍方面的作用,并研究了射频消融(RFA)对逆转这种不良影响的作用。

方法

研究了86例患有PVC且LVEF正常的患者以及33名LVEF正常的正常对照者。50例PVC患者在消融组,36例在非消融组。在消融前后,通过心音图(Audicor,Inovise Medical,Inc.,美国俄勒冈州比弗顿)测量窦性心律(SR)期间的机电激活时间百分比(%EMAT)、左心室收缩时间百分比(%LVST)、第三心音(S3)和第四心音(S4)以及收缩功能障碍指数(SDI)。在28例患者中,在不同时间对单个患者10秒Audicor记录中无PVC的SR、有单个PVC、≥2个PVC或室性心动过速的SR期间的声学参数进行了比较。使用24小时心音图和心音图动态心电图记录评估41例患者中PVC负荷对机电功能的影响。

结果

与对照组相比,PVC组的%EMAT、S3、S4和SDI显著恶化。在10秒记录条中,随着PVC数量增加,%EMAT和SDI恶化。随着PVC负荷增加,%EMAT呈显著线性增加。PVC患者消融后,%EMAT、%LVST、S3、S4和SDI有显著改善。

结论

心音图可检测LVEF正常患者中PVC引起的轻微机电功能障碍。RFA可逆转这种不良影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验