Suppr超能文献

小腿骨折患者使用步行靴时,压力中心会向后移动。

Center of pressure in a walking boot shifts posteriorly in patients following lower leg fracture.

作者信息

Lajevardi-Khosh Arad, Bamberg Stacy, Rothberg David, Kubiak Erik, Petelenz Tomasz, Hitchcock Robert

机构信息

Department of Bioengineering, University of Utah, 36 S. Wasatch Drive, Rm. 4509, Salt Lake City, UT, 84112, USA.

Department of Orthopaedics, University of Utah Hospitals and Clinics, 590 Wakara Way, Salt Lake City, UT, 84108, USA.

出版信息

Gait Posture. 2019 May;70:218-221. doi: 10.1016/j.gaitpost.2019.03.010. Epub 2019 Mar 16.

Abstract

BACKGROUND

Studies have shown that the ambulatory behavior and amount of weight bearing performed by lower leg fracture patients, increases over time. It is likely that gait features, such as center of pressure (CoP), also change over time.

RESEARCH QUESTION

The purpose of this study was to characterize changes in CoP exhibited by lower leg fracture patients wearing a walking boot during the recovery period.

METHODS

Approximately 2 weeks post-surgery, seven lower leg fracture patients were fitted with a MaxTrax walking boot which was integrated with the Ambulatory Tibia Load Analysis System, an underfoot load monitoring system. Patients wore the walking boot for 2-12 weeks resulting in continuous load data during the recovery period. Ambulation was filtered from the raw data and daily average CoP values were calculated by averaging the CoP vectors from all steps in a given day.

RESULT

In general, the CoP vector varied in both the x and y directions during the initial stages of recovery but was more uniform during the later stages of healing. In 6/7 patients, the CoP in the y direction was closer to the forefoot during the initial stages of healing but shifted posteriorly as time post-surgery increased. The single patient that did not exhibit a posterior shift in CoP was also the only patient to develop a non-union. CoP in the x direction show a less clear trend. CoP in the x direction exhibited a medial shift in 5 patients and a lateral shift in 2 patients.

SIGNIFICANCE

During lower leg fracture recovery in a walking boot, the CoP in the y direction shifts posteriorly as time post-surgery increases and CoP monitoring may become a useful tool to monitor individual patient healing progression.

摘要

背景

研究表明,小腿骨折患者的动态行为和负重程度会随着时间增加。诸如压力中心(CoP)等步态特征可能也会随时间变化。

研究问题

本研究的目的是描述小腿骨折患者在恢复期穿着步行靴时压力中心的变化特征。

方法

术后约2周,7名小腿骨折患者穿上与动态胫骨负荷分析系统(一种足底负荷监测系统)集成的MaxTrax步行靴。患者穿着步行靴2至12周,从而在恢复期获得连续的负荷数据。从原始数据中筛选出步行数据,并通过对给定日期内所有步幅的压力中心向量求平均来计算每日平均压力中心值。

结果

一般来说,在恢复初期,压力中心向量在x和y方向上都有变化,但在愈合后期更为均匀。在6/7的患者中,在愈合初期,y方向的压力中心更靠近前足,但随着术后时间的增加向后移动。唯一一名压力中心没有向后移动的患者也是唯一一名出现骨不连的患者。x方向的压力中心趋势不太明显。5名患者的x方向压力中心出现内侧移动,2名患者出现外侧移动。

意义

在穿着步行靴进行小腿骨折恢复期间,随着术后时间的增加,y方向的压力中心向后移动,压力中心监测可能成为监测个体患者愈合进程的有用工具。