Suppr超能文献

双甲基丙烯酸缩水甘油酯和基于聚氨酯改性双甲基丙烯酸缩水甘油酯的树脂复合材料的体内生物降解

In Vivo Biodegradation of bisGMA and Urethane-Modified bisGMA-Based Resin Composite Materials.

作者信息

MacAulay M, Tam L E, Santerre J P, Finer Y

机构信息

1 Faculty of Dentistry, University of Toronto, Toronto, Ontario, Canada.

2 Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada.

出版信息

JDR Clin Trans Res. 2017 Oct;2(4):397-405. doi: 10.1177/2380084417722117. Epub 2017 Jul 21.

Abstract

The aim of this study was to compare the levels of in vivo chemical degradation sustained by bisphenyl-glycidyl-dimethacrylate (bisGMA)-based and urethane-modified bisGMA-based resin composites. A cohort of 58 patients was recruited for the study. Human salivary esterase activity (HSDE) was measured for each patient prior to restoration placement. Class V or III composite restorations without occlusal contacts were placed in adult patients using a 3-step adhesive (Scotchbond MP, 3M) and 1 of 2 resin composites: a traditional bisGMA-based (Z250; 3M) ( n = 28) or a urethane-modified bisGMA-based composite (TPH Spectra, Dentsply) ( n = 30). Patients followed a 2-min rinse (saline containing 20% ethanol) protocol before, immediately after, and 7 days after restoration placement. The rinse samples were analyzed for the presence of bisphenol A (BPA) and bishydroxypropoxyphenylpropane (bisHPPP), a bisGMA breakdown product, using high-performance liquid chromatography in combination with mass spectrometry. The overall mean ± standard error (SE) HSDE activity was 23.4 ± 1.9 U/mL, with no statistical difference between the Z250 (22.6 ± 2.8 U/mL) and TPH (24.1 ± 2.1 U/mL) groups ( P = 0.69). BPA was not detected from any rinse samples. BisHPPP was detected from both composites only in rinse samples immediately after resin composite placement (0.59 µg/mm ± 0.16 and 0.68 µg/mm ± 0.16 for Z250 and TPH, respectively, P = 0.767). There was no statistically significant correlation between HSDE and amount of bisHPPP obtained from the saliva for the Z250 group ( r = 0.071, P = 0.723), TPH group ( r = 0.266, P = 0.155), and both groups combined ( r = 0.080, P = 0.549). Conventional commercial resin composite materials used in the current study did not release any detectable amount of BPA and only showed detectable levels of bisHPPP for a short term after placement, suggesting that hydrolytic consumption of any available resin substrate is fast and the generated products are rapidly diluted below the detection level limit (<20 ppb) in the oral cavity. This short-term release of bisHPPP was not significantly affected by material type or esterase level in the saliva. Knowledge Transfer Statement: This clinical study demonstrated that the duration and degree of biodegradation of 2 representative formulations of resin composites was limited in both duration and amounts of detectable matrix derived degradation products. No significant level of potential biohazards was released following the application of the resin composites. The results of this study can help oral care professionals address concerns from their patients about possible health issues regarding the application of resin composite restorative materials.

摘要

本研究的目的是比较双酚 - 缩水甘油基二甲基丙烯酸酯(bisGMA)基和聚氨酯改性的bisGMA基树脂复合材料在体内的化学降解水平。本研究招募了58名患者。在进行修复前,对每位患者测量人唾液酯酶活性(HSDE)。使用三步粘结剂(Scotchbond MP,3M)和两种树脂复合材料中的一种,在成年患者中放置无咬合接触的V类或III类复合修复体:传统的bisGMA基材料(Z250;3M)(n = 28)或聚氨酯改性的bisGMA基复合材料(TPH Spectra,登士柏)(n = 30)。患者在修复体放置前、放置后立即以及放置后7天遵循2分钟的冲洗方案(含20%乙醇的盐水)。使用高效液相色谱结合质谱分析冲洗样品中双酚A(BPA)和双GMA分解产物双羟基丙氧基苯基丙烷(bisHPPP)的存在情况。HSDE活性的总体均值±标准误(SE)为23.4±1.9 U/mL,Z250组(22.6±2.8 U/mL)和TPH组(24.1±2.1 U/mL)之间无统计学差异(P = 0.69)。在任何冲洗样品中均未检测到BPA。仅在树脂复合材料放置后立即的冲洗样品中从两种复合材料中检测到bisHPPP(Z250和TPH分别为0.59 μg/mm±0.16和0.68 μg/mm±0.16,P = 0.767)。对于Z250组(r = 0.071,P = 0.723)、TPH组(r = 0.266,P = 0.155)以及两组合并(r = 0.080,P = 0.549),HSDE与从唾液中获得的bisHPPP量之间均无统计学显著相关性。本研究中使用的传统商用树脂复合材料未释放任何可检测量的BPA,并且仅在放置后短期内显示出可检测水平的bisHPPP,这表明任何可用树脂底物的水解消耗很快,并且生成的产物在口腔中迅速稀释至检测水平极限以下(<20 ppb)。bisHPPP的这种短期释放不受材料类型或唾液中酯酶水平的显著影响。知识转移声明:本临床研究表明,两种代表性树脂复合材料配方的生物降解持续时间和程度在可检测的基质衍生降解产物的持续时间和量方面均有限。树脂复合材料应用后未释放出显著水平的潜在生物危害。本研究结果可帮助口腔护理专业人员解决患者对树脂复合修复材料应用可能存在的健康问题的担忧。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验