de Lima Feltraco Lizot Lilian, da Silva Anne Caroline Cezimbra, Bastiani Marcos Frank, Hahn Roberta Zilles, Bulcão Rachel, Perassolo Magda Susana, Antunes Marina Venzon, Linden Rafael
Laboratory of Analytical Toxicology, Feevale University, Novo Hamburgo, Brazil; National Institute of Science and Technology in Forensic Sciences (INCT Forense), Brazil; Graduate Program on Toxicology and Analytical Toxicology, Universidade Feevale, Novo Hamburgo, RS, Brazil.
Laboratory of Analytical Toxicology, Feevale University, Novo Hamburgo, Brazil; Graduate Program on Toxicology and Analytical Toxicology, Universidade Feevale, Novo Hamburgo, RS, Brazil.
Forensic Sci Int. 2019 May;298:408-416. doi: 10.1016/j.forsciint.2019.03.026. Epub 2019 Mar 23.
Cocaine (COC) is one of the most widely abused drugs in the world and its sensitive and its reliable measurement in blood is of great importance in the field of forensic and clinical toxicology. Additionally, the determination of COC metabolites such as benzoylecgonine (BZE), cocaethylene (CE), ecgonine methyl ester (EME), and norcocaine (NCOC) are also of complementary diagnostic value. The quantification of COC and metabolites in dried blood spots (DBS) may be an alternative to conventional collection methods with several advantages, including easier, on-site, collection, transportation and storage. In this study, we present a simple and comprehensively validated UPLC-MS/MS assay to measured COC, BZE, EME, NCOC and CE in DBS. The evaluated assay was linear from 5-500 ng mL. Precision assays presented CV% of 1.27-6.82, and accuracy in the range of 97-113.78%. Low haematocrit values had a negative impact in the assay accuracy. COC, BE, NCOC and CE measurements can be made reliably in DBS stored for 14 days at room temperature, as well as at -20 °C and 45 °C. All evaluated compounds can be measured in DBS maintained at -20 °C for 14 days. DBS sampling can be used for the clinical evaluation of the exposure to COC, being an alternative for collection, short-term storage and transportation of blood at room and high temperatures.
可卡因(COC)是世界上滥用最为广泛的毒品之一,在法医和临床毒理学领域,对其在血液中进行灵敏且可靠的检测至关重要。此外,对可卡因代谢物如苯甲酰爱康宁(BZE)、可卡因乙烯酯(CE)、爱康宁甲酯(EME)和去甲可卡因(NCOC)的测定也具有辅助诊断价值。干血斑(DBS)中可卡因及其代谢物的定量分析可能是传统采集方法的一种替代方案,具有诸多优势,包括采集更容易、可在现场进行,以及便于运输和储存。在本研究中,我们提出了一种简单且经过全面验证的超高效液相色谱 - 串联质谱(UPLC-MS/MS)分析法,用于测定干血斑中的COC、BZE、EME、NCOC和CE。所评估的分析方法在5 - 500 ng/mL范围内呈线性。精密度分析的变异系数(CV%)为1.27 - 6.82,准确度在97 - 113.78%范围内。低血细胞比容值对分析准确度有负面影响。在室温下储存14天以及在 -20°C和45°C条件下储存的干血斑中,均可可靠地测定COC、BE、NCOC和CE。所有评估的化合物均可在 -20°C下储存14天的干血斑中进行测定。干血斑采样可用于可卡因暴露的临床评估,是在室温和高温下采集、短期储存和运输血液的一种替代方法。