Suppr超能文献

肩部旋转缆索的大体及显微解剖结构

Macroscopic and microscopic anatomy of the rotator cable in the shoulder.

作者信息

Arai Ryuzo, Matsuda Shuichi

机构信息

Department of Orthopaedic Surgery, Graduate School of Medicine and Faculty of Medicine, Kyoto University, 54, Shogoin Kawahara-cho, Sakyo-ku, Kyoto City, Kyoto Pref, 606-8507, Japan.

Department of Orthopaedic Surgery, Graduate School of Medicine and Faculty of Medicine, Kyoto University, 54, Shogoin Kawahara-cho, Sakyo-ku, Kyoto City, Kyoto Pref, 606-8507, Japan.

出版信息

J Orthop Sci. 2020 Mar;25(2):229-234. doi: 10.1016/j.jos.2019.03.014. Epub 2019 Apr 9.

Abstract

BACKGROUND

The rotator cable, a semicircular fiber bundle in the lateral portion of the rotator cuff, has been believed to transmit forces among cuff tendons. This study was performed to clarify the functional anatomy of the rotator cable through histoanatomical methods.

METHODS

Twenty-two cuff-intact shoulders of fixed cadavers were dissected. The cable was investigated from the cuff surface and articular/bursal sides of the capsule. The width of the cable and distances from the capsule attachment to both of the lateral and medial borders of the cable were measured, and their correlations to the humeral head diameter were calculated. The location of the cable on the humeral head was observed and recorded. In additional five shoulders the cuff/capsule complex and greater tubercle were harvested en block and histologically investigated.

RESULTS

The rotator cable was evident in the capsule of 14 shoulders. One specimen demonstrated the cable of double curves. The capsule thickness alteration corresponding to the medial border of the cable with a single curve existed approximately on the so-called 'flexion point' where the humerus started to form a spherical curve from the greater tubercle to the joint surface. The 'flexion point' macroscopically corresponded to the medial boundary of the contact area between the cuff and head. The distance between the cable and capsule attachment showed marked negative correlation to the head diameter. Histologically the cable demonstrated cartilaginous metaplasia and vertical fiber orientation to the supraspinatus.

CONCLUSIONS

The rotator cable does not always exist in all the shoulders and its appearances are varied. The location and cartilaginous metaplasia of the cable suggested compression force between the cuff and humeral head, and the force would help cable creation in capsule layer. The vertical fiber orientation of the cable to the supraspinatus would be unlikely to explain force transmission among the cuff tendons.

摘要

背景

肩袖缆线是肩袖外侧部分的半圆形纤维束,一直被认为在肩袖肌腱之间传递力量。本研究旨在通过组织解剖学方法阐明肩袖缆线的功能解剖结构。

方法

对22具固定尸体的完整肩袖肩部进行解剖。从肩袖表面以及关节囊/滑囊侧对缆线进行研究。测量缆线的宽度以及从关节囊附着处到缆线外侧和内侧边界的距离,并计算它们与肱骨头直径的相关性。观察并记录缆线在肱骨头的位置。另外在5个肩部将肩袖/关节囊复合体和大结节整块取下并进行组织学研究。

结果

14个肩部的关节囊中可见肩袖缆线。1个标本显示为双曲缆线。对应于单曲线缆线内侧边界的关节囊厚度变化大约存在于所谓的“屈曲点”,即肱骨从大结节到关节面开始形成球形曲线的位置。“屈曲点”在宏观上对应于肩袖与肱骨头接触区域的内侧边界。缆线与关节囊附着处之间的距离与肱骨头直径呈显著负相关。组织学上,缆线显示软骨化生以及与冈上肌垂直的纤维方向。

结论

并非所有肩部都存在肩袖缆线,其表现各异。缆线的位置和软骨化生表明肩袖与肱骨头之间存在压缩力,且该力有助于在关节囊层形成缆线。缆线与冈上肌垂直的纤维方向不太可能解释肩袖肌腱之间的力传递。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验