Suppr超能文献

在尝试清洁收集尿液之前对婴儿进行即时超声检查:一项随机对照试验。

Point-of-care ultrasound before attempting clean-catch urine collection in infants: a randomized controlled trial.

机构信息

Department of Pediatrics, Division of Emergency Medicine, CHU Sainte-Justine, Université de Montréal, Montréal, QC.

出版信息

CJEM. 2019 Sep;21(5):646-652. doi: 10.1017/cem.2019.30.

Abstract

OBJECTIVE

A new non-invasive bladder stimulation technique has been described to obtain clean-catch urine specimens in infants. This study aimed to evaluate if point-of-care ultrasound (POCUS) guided feeding protocol to measure bladder volume prior to stimulation techniques improves clean-catch urine collection success.

METHODS

A prospective randomized controlled trial study was conducted in a tertiary care pediatric emergency department. Infants aged less than 6 months needing a urine sample were randomized to either POCUS group or feeding group (standard procedure) before performing a standardized clean-catch urine stimulation technique. In the POCUS group, a feeding period was permitted if the bladder width was less than 2 cm, otherwise the clean-catch urine was performed immediately. The primary outcome was the success of the procedure defined by the collection of at least 2 mL of urine, obtained within 300 seconds of bladder stimulation manoeuvres. It was estimated that the recruitment of 200 children was necessary to yield 80% power to identify an improvement of 20% in the success rate.

RESULTS

A total of 201 infants were included. The procedure was not more successful in the POCUS group (48%) compared to the feeding group (54%) (Difference: 6.5%; 95% CI: -7.3 to 19.8%). The mean time to collect urine samples from randomization to sample collection was not different between the two groups.

CONCLUSIONS

Our study failed to show a benefit of using POCUS to improve the success rate of stimulated clean-catch urine. Moreover, the importance of the feeding period prior to clean-catch urine manoeuvres should be evaluated further.

CLINICAL TRIAL REGISTRATION

NCT02751671.

摘要

目的

已经描述了一种新的非侵入性膀胱刺激技术,以获取婴儿的清洁尿标本。本研究旨在评估在刺激技术之前使用即时超声(POCUS)引导喂养方案测量膀胱容量是否能提高清洁尿采集成功率。

方法

在一家三级儿科急诊病房进行了一项前瞻性随机对照试验研究。需要尿液样本的年龄小于 6 个月的婴儿被随机分配到 POCUS 组或喂养组(标准程序),然后再进行标准化的清洁尿刺激技术。在 POCUS 组,如果膀胱宽度小于 2 厘米,则允许进行喂养期,否则立即进行清洁尿采集。主要结局是通过膀胱刺激操作后 300 秒内收集至少 2 毫升尿液的程序成功定义。估计需要招募 200 名儿童才能达到 80%的效力,以确定成功率提高 20%。

结果

共纳入 201 名婴儿。与喂养组(54%)相比,POCUS 组(48%)的操作成功率没有更高(差异:6.5%;95%CI:-7.3 至 19.8%)。从随机分组到采集样本的尿液采集时间在两组之间没有差异。

结论

我们的研究未能表明使用 POCUS 提高刺激清洁尿采集成功率的益处。此外,应进一步评估清洁尿操作前喂养期的重要性。

临床试验注册号

NCT02751671。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验