Al Sergani Hani, Galzerano Domenico, Vriz Olga, Al Buraiki Jehad
The Heart Centre, King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia.
Alfaisal University, College of Medicine, Riyadh, Saudi Arabia.
J Cardiovasc Echogr. 2019 Jan-Mar;29(1):14-16. doi: 10.4103/jcecho.jcecho_56_18.
We describe a case of a 77-year-old male who underwent transcatheter aortic valve implantation (TAVR) with Edwards SAPIEN XT size 26 mm for severe aortic stenosis. Postprocedural transesophageal echocardiography (TEE) showed left-to-right shunt between the left ventricular outflow tract just below the bioprosthesis and the right atrium across the atrioventricular septum (Gerbode defect). Three-dimensional echocardiography (3DE) allowed a detailed anatomical imaging of the shape and the location of a small, circular, atrioventricular defect that was a type II, direct, supravalvular, Gerbode-type defect. This is the third report of a Gerbode defect after TAVR whose diagnosis has important implications on clinical decision-making. TEE plays a key role; its diagnostic ability is enriched by the additional value of 3DE.
我们描述了一例77岁男性患者,因严重主动脉瓣狭窄接受了经导管主动脉瓣植入术(TAVR),使用的是26 mm的爱德华兹SAPIEN XT瓣膜。术后经食管超声心动图(TEE)显示,在生物瓣膜下方的左心室流出道与右心房之间,经房室间隔(Gerbode缺损)存在左向右分流。三维超声心动图(3DE)能够对一个小的圆形房室缺损的形状和位置进行详细的解剖成像,该缺损为II型、直接、瓣上型Gerbode型缺损。这是TAVR术后Gerbode缺损的第三例报告,其诊断对临床决策具有重要意义。TEE起着关键作用;3DE的附加价值增强了其诊断能力。