[Phono-mechanographic evaluation of aortic stenoses. Contribution of the B1-maximum murmur/B1-B2 index].

作者信息

Guénot O, Desnos M, Cristofini P, Fernandez F, Baragan J, Gay J

出版信息

Arch Mal Coeur Vaiss. 1986 Nov;79(12):1786-92.

PMID:3105491
Abstract

The diagnostic value of phonomechanography in valvular aortic stenosis was reassessed with a rarely used index, the ratio S1-maximum intensity of the systolic murmur/S1-S2, or Thiron's index, the author of which only studied the correlations with the aortic transvalvular pressure gradient. The results obtained by the author being considered inconclusive, we decided to examine its correlations with aortic valve surface area calculated with the Gorlin's formula. The study was carried out in 38 patients with pure aortic stenosis, in whom 4 phonomechanographic parameters, the corrected left ventricular ejection time (Meiners), the carotid pulse half peak time, the S1-maximum intensity of the murmur interval and Thiron's index, were compared with the transvalvular pressure gradient and the aortic valve surface area at catheterisation. The first two parameters mentioned above were of limited value (correlations with aortic valve surface area r = 0.315, p less than 0.05 and r = 0.477, p less than 0.01 respectively). On the other hand, a good correlation was obtained with Thiron's index (r = 0.624, p less than 0.001) which was better than that found with the interval between S1 and maximum intensity of the systolic murmur (r = 0.483, p less than 0.001) in a population not excluding subjects with cardiac failure. These results indicate that: when Thiron's index less than or equal to 0.45, the aortic stenosis is probably mild (aortic surface area greater than 0.8 cm2), when Thiron's index is 0.46 greater than 0.56, the aortic stenosis is likely to be moderately severe (aortic surface area 0.8 less than 0.5 cm2), when Thiron's index is greater than 0.57, the aortic stenosis is probably severe (aortic surface area less than 0.5 cm2). In our series, Thiron's index was the best phonomechanographic parameter for the assessment of pure aortic stenosis. It could not be calculated in 10 out of 48 patients; this drawback was not encountered with the corrected left ventricular ejection time or the carotid pulse half peak time.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
[Phono-mechanographic evaluation of aortic stenoses. Contribution of the B1-maximum murmur/B1-B2 index].
Arch Mal Coeur Vaiss. 1986 Nov;79(12):1786-92.
2
[Evaluation of the seriousness of aortic valve stenosis: calculation of the valvular area or peak? Reliability of Hakki's formula].[主动脉瓣狭窄严重程度的评估:瓣膜面积计算还是峰值计算?哈基公式的可靠性]
G Ital Cardiol. 1985 May;15(5):502-6.
3
[Comparison of pulsed and continuous Doppler techniques for the evaluation of left ventricular stenoses].[用于评估左心室狭窄的脉冲多普勒技术与连续多普勒技术的比较]
Arch Mal Coeur Vaiss. 1985 Oct;78(10):1473-83.
4
Progression of aortic stenosis in the elderly detected by noninvasive methods.通过非侵入性方法检测老年人主动脉瓣狭窄的进展情况。
Bull Tokyo Med Dent Univ. 1988 Jun;35(1-2):19-24.
5
[Various etiologies of systolic murmurs radiating from the apex of the heart to the neck].[从心尖向颈部传导的收缩期杂音的各种病因]
Sem Hop. 1975 Mar 14;51(13):855-70.
6
[Phonomechanographic assessment of the transvalvular gradient in aortic stenosis. Study of the index : S1--maximal intensity of murmur / S1--S2].[主动脉瓣狭窄跨瓣压差的音机械图评估。指标研究:S1(杂音最大强度)/ S1 - S2]
Arch Mal Coeur Vaiss. 1981 Jan;74(1):29-40.
7
Aortic valve replacement in true severe aortic stenosis with low gradient and low ejection fraction.真正的重度主动脉瓣狭窄伴低跨瓣压差和低射血分数时的主动脉瓣置换术。
Heart Surg Forum. 2006;9(4):E681-5. doi: 10.1532/HSF98.20061039.
8
[Evaluation of the degree of mitral stenosis : reassessment of the M mode echocardiographic index].[二尖瓣狭窄程度的评估:M型超声心动图指标的重新评估]
Arch Mal Coeur Vaiss. 1984 Apr;77(4):442-50.
9
[Continuous emission Doppler study with spectrum analysis in the evaluation of aortic stenosis in adults. Apropos of 30 cases].[连续发射多普勒频谱分析研究在成人主动脉瓣狭窄评估中的应用。附30例报告]
Arch Mal Coeur Vaiss. 1987 Mar;80(3):328-33.
10
Gender differences in left ventricular function in patients with isolated aortic stenosis.单纯主动脉瓣狭窄患者左心室功能的性别差异
J Heart Valve Dis. 2003 May;12(3):313-8.