Suppr超能文献

基于磁性电极磁预富集的均相电化学发光免疫分析用于生物标志物的检测。

Homogeneous electrogenerated chemiluminescence immunoassay for the detection of biomarkers by magnetic preconcentration on a magnetic electrode.

机构信息

Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, Shaanxi, China.

出版信息

Anal Bioanal Chem. 2019 Jul;411(18):4203-4211. doi: 10.1007/s00216-019-01830-1. Epub 2019 May 6.

Abstract

A homogeneous electrogenerated chemiluminescence (ECL) immunoassay for highly sensitive quantification of specific biomarkers based on immunomagnetic beads and homogeneous detection on a magnetic electrode was developed, for the first time. The magnetic electrode is made of a glassy carbon electrode and a series of ring permanent magnets. D-Dimer antigen was taken as a model analyte while biotinylated D-dimer antibody bound on the streptavidin-coated magnetic beads was utilized as a magnetic capture probe and ruthenium complex-labeled D-dimer antibody was employed as an ECL probe. After a fixed amount of magnetic capture probe and the ECL probe was introduced into analyte D-dimer solution, the "sandwich" immunoconjugates on the magnetic beads were formed in tested solution and then magnetically concentrated on the surface of the magnetic electrode. The homogeneous ECL immunoassay for quantification of specific biomarker was directly carried out in the presence of co-reactant tripropylamine. The low detection limit of 1 ng/mL in magnetic enrich time of 2 min and the good magnetic regeneration for the detection of D-dimer were achieved. The magnetic bead shield ECL emission was extensively discussed. This work demonstrates that the homogeneous (separation-free) ECL immunoassay using magnetic beads and magnetic electrode is a promising approach to quantify the biomarkers with high sensitivity and selectivity and in a short time. This approach can be easily extended to ECL and electrochemical biosensing for other biomarkers. Graphical abstract.

摘要

首次基于免疫磁珠和均相检测在磁性电极上开发了用于高度灵敏定量特定生物标志物的均相电化学发光 (ECL) 免疫分析。磁性电极由玻碳电极和一系列环形永磁体组成。D-二聚体抗原被用作模型分析物,而结合在链霉亲和素包被的磁珠上的生物素化 D-二聚体抗体被用作磁性捕获探针,并且钌复合物标记的 D-二聚体抗体被用作 ECL 探针。将固定量的磁性捕获探针和 ECL 探针引入分析物 D-二聚体溶液后,在测试溶液中形成磁珠上的“三明治”免疫复合物,然后将其磁性浓缩到磁性电极的表面。在存在共反应物三丙胺的情况下,直接进行用于定量特定生物标志物的均相 ECL 免疫分析。在 2 分钟的磁性富集时间内实现了 1ng/mL 的低检测限,并且对 D-二聚体的检测具有良好的磁性再生能力。广泛讨论了磁珠屏蔽 ECL 发射。这项工作表明,使用磁性珠和磁性电极的均相(无需分离)ECL 免疫分析是一种很有前途的方法,可以高灵敏度和选择性地在短时间内定量生物标志物。该方法可以轻松扩展到其他生物标志物的 ECL 和电化学生物传感。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验