• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

汉考克猪异种移植物的罕见并发症:主动脉根部支柱受压

Unusual complication of the Hancock porcine heterograft: strut compression in the aortic root.

作者信息

Salomon N W, Copeland J G, Goldman S, Larson D F

出版信息

J Thorac Cardiovasc Surg. 1979 Feb;77(2):294-6.

PMID:310916
Abstract

A 65-year-old man underwent aortic valve replacement and triple coronary artery bypass grafting which were followed by gradual late postoperative thrombosis of his 25 mm. Hancock porcine aortic heterograft. At reoperation, the valve struts were noted to be angled centrally into the aortic lumen and dense thrombus completely filled all three sinuses. After valve removal and extensive debridement of the aortic anulus, including relaxing incisions, a diameter of only 23 mm. was obtained. A 23 mm. Björk-Shiley aortic prosthesis was inserted and the patient's recovery was uneventful. This previously unreported complication resulted from the insertion of a too-large Hancock porcine heterograft into a relatively small aortic root, resulting in circumferential strut compression, impedance of central flow, and subsequent valve thrombosis.

摘要

一名65岁男性接受了主动脉瓣置换术和三支冠状动脉搭桥术,术后其25毫米的汉考克猪主动脉异种移植瓣膜逐渐出现晚期血栓形成。再次手术时,发现瓣膜支柱向主动脉腔中心成角,致密血栓完全充满了所有三个窦。在移除瓣膜并对主动脉瓣环进行广泛清创,包括松弛切口后,仅获得了23毫米的直径。植入了一个23毫米的比约克-希利主动脉假体,患者恢复顺利。这种先前未报道的并发症是由于将过大的汉考克猪异种移植瓣膜植入相对较小的主动脉根部,导致周向支柱受压、中心血流受阻以及随后的瓣膜血栓形成。

相似文献

1
Unusual complication of the Hancock porcine heterograft: strut compression in the aortic root.汉考克猪异种移植物的罕见并发症:主动脉根部支柱受压
J Thorac Cardiovasc Surg. 1979 Feb;77(2):294-6.
2
Aortic valve replacement with the Hancock standard, Björk-Shiley, and Lillehei-Kaster prostheses. A comparison based on follow-up from 1 to 15 years.采用汉考克标准型、比约克-希利型和 Lillehei-Kaster 型人工瓣膜进行主动脉瓣置换术。基于 1 至 15 年随访的比较。
J Thorac Cardiovasc Surg. 1989 Jul;98(1):37-47.
3
[A case of myonephropathic-metabolic syndrome after urgent aortic valve re-replacement due to prosthetic valve thrombosis].
Kyobu Geka. 1990 Jul;43(7):565-8.
4
Acute bioprosthetic thrombosis immediately after aortic valve replacement.主动脉瓣置换术后立即发生的急性生物瓣血栓形成。
J Cardiovasc Med (Hagerstown). 2009 Feb;10(2):167-9. doi: 10.2459/JCM.0b013e32831a9a98.
5
Late results of heart valve replacement with the Hancock II bioprosthesis.汉考克二代生物瓣膜心脏瓣膜置换术的远期结果
J Thorac Cardiovasc Surg. 2001 Feb;121(2):268-77. doi: 10.1067/mtc.2001.112208.
6
Composite aortic root replacement with direct coronary artery implantation.带直接冠状动脉植入的复合主动脉根部置换术。
Ann Thorac Surg. 1996 Oct;62(4):1090-5. doi: 10.1016/0003-4975(96)00487-0.
7
Late results of valve replacement with the Björk-Shiley valve (1973 to 1982).使用Björk-Shiley瓣膜进行瓣膜置换的远期结果(1973年至1982年)。
J Thorac Cardiovasc Surg. 1993 Feb;105(2):302-12.
8
[Morbidity and mortality seen in patients with a Hancock bioprosthesis, followed for more than 5 years. Experience at the La Pitié Hospital].[汉考克生物假体患者随访5年以上的发病率和死亡率。拉皮提医院的经验]
Arch Mal Coeur Vaiss. 1988 Jan;81(1):49-54.
9
Aortic biological valve thrombosis in an HIV positive patient.HIV 阳性患者的主动脉生物瓣血栓形成。
Ann Thorac Surg. 2011 Jun;91(6):e90-1. doi: 10.1016/j.athoracsur.2011.01.099.
10
Postimplantation morphologic changes of glutaraldehyde-fixed porcine aortic roots and risk of aneurysm and rupture.戊二醛固定猪主动脉根部植入后的形态学变化以及动脉瘤和破裂风险
J Thorac Cardiovasc Surg. 2009 Jan;137(1):94-100. doi: 10.1016/j.jtcvs.2008.07.004. Epub 2008 Sep 14.

引用本文的文献

1
Failure of a bioprosthetic mitral valve due to attachment of a residual chorda.生物二尖瓣因残留腱索附着而功能失效。
Thorax. 1986 Aug;41(8):652-3. doi: 10.1136/thx.41.8.652.