Department of Radiology, Virgen de la Arrixaca University Clinical Hospital, University of Murcia, Murcia, Spain.
Institute of Biomedical Research (IMIB), Virgen de la Arrixaca University Clinical Hospital, University of Murcia, Murcia, Spain.
PLoS One. 2019 May 23;14(5):e0217297. doi: 10.1371/journal.pone.0217297. eCollection 2019.
The aim of this study was to compare in vivo vs ex vivo liver stiffness in rats with acoustic radiation force impulse (ARFI) elastography using the histological findings as the gold standard.
Eighteen male Wistar rats aged 16-18 months were divided into a control group (n = 6) and obese group (n = 12). Liver stiffness was measured with shear wave velocity (SWV) using the ARFI technique both in vivo and ex vivo. The degree of fibrosis, steatosis and liver inflammation was evaluated in the histological findings. Pearson's correlation coefficient was applied to relate the SWV values to the histological parameters.
The SWV values acquired in the ex vivo study were significantly lower than those obtained in vivo (P < 0.004). A significantly higher correlation value between the degree of liver fibrosis and the ARFI elastography assessment was observed in the ex vivo study (r = 0.706, P < 0.002), than the in vivo study (r = 0.623, P < 0.05).
Assessment of liver stiffness using ARFI elastography yielded a significant correlation between SWV and liver fibrosis in both the in vivo and ex vivo experiments. We consider that by minimising the influence of possible sources of artefact we could improve the accuracy of the measurements acquired with ARFI.
本研究旨在使用组织学发现作为金标准,比较大鼠声辐射脉冲力(ARFI)弹性成像的体内与离体肝硬度。
将 18 只 16-18 月龄雄性 Wistar 大鼠分为对照组(n = 6)和肥胖组(n = 12)。使用 ARFI 技术分别在体内和离体测量剪切波速度(SWV)以测量肝硬度。在组织学发现中评估纤维化、脂肪变性和肝炎症的程度。应用 Pearson 相关系数将 SWV 值与组织学参数相关联。
在离体研究中获得的 SWV 值明显低于体内研究(P < 0.004)。在离体研究中观察到肝纤维化程度与 ARFI 弹性成像评估之间的相关性更高(r = 0.706,P < 0.002),而在体内研究中相关性较低(r = 0.623,P < 0.05)。
使用 ARFI 弹性成像评估肝硬度,在体内和离体实验中,SWV 与肝纤维化之间均存在显著相关性。我们认为,通过最小化可能的伪影来源的影响,我们可以提高 ARFI 测量的准确性。