Maliba Pharmacy College, Uka Tarsadia University, Surat 394350, India.
Maliba Pharmacy College, Uka Tarsadia University, Surat 394350, India.
Int J Pharm. 2019 Jul 20;566:513-519. doi: 10.1016/j.ijpharm.2019.06.008. Epub 2019 Jun 5.
The optical and swelling properties of gatifloxacin-loaded contact lens decrease owing to the precipitation of gatifloxacin (on hydration) in the matrix structure of the contact lens. This paper focuses on the use of Pluronic F68 both inside and outside (in the packaging solution) the contact lens to form micelles to dissolve the gatifloxacin precipitates and not limited to sustain the release of gatifloxacin. The aim of this study was to screen the critical variables affecting the optical and swelling properties of gatifloxacin-loaded contact lens. The independent variables investigated were the concentration of Pluronic F68 incorporated in the monomer solution to fabricate the lens (X, %w/v), the concentration of Pluronic F68 in the packaging solution (X %w/v), the concentration of gatifloxacin incorporated in the monomer solution (X %w/v), the concentration of gatifloxacin incorporated in the packaging solution during autoclave (X, %w/v), the concentration of gatifloxacin incorporated in the packaging solution during extraction (X, %w/v), the time (stabilization time) after the addition of gatifloxacin and Pluronic F68 to the monomer solution before the fabrication of the lens (X, h), the pH of the packaging solution (X), the temperature of the extracted solution (X, °C), and the curing time for fabricating the contact lens (X, min). The gatifloxacin-loaded contact lenses were characterized for their optical transmittances after sterilization on day 1 (Y, %), optical transmittances after 7 days of sterilization (Y, %) and swelling percentages after 7 days of sterilization (Y, %). The selected variables showed responses that were in the ranges 53.5% to 97.2%, 51.3% to 92.6%, and 50.3% to 83.7% for Y, Y, and Y, respectively. The data suggest that the presence of Pluronic F68 inside the contact lens (X) reduced the optical and swelling properties of the contact lens, whereas the presence of Pluronic F68 in the packaging solution (X) improved them through micelle formation. The other variables (X to X) did not exhibit significant effects on the swelling and transmittance. This study revealed the potential of Plackett-Burman design to screen the selected critical variables that affected the optical and swelling properties of gatifloxacin-loaded contact lens.
载氟沙星隐形眼镜的光学和溶胀性能下降,这是由于载氟沙星(水合后)在隐形眼镜基质结构中沉淀所致。本文重点研究了在隐形眼镜内外(在包装溶液中)使用 Pluronic F68 形成胶束以溶解载氟沙星沉淀物,而不是仅仅持续释放载氟沙星。本研究的目的是筛选影响载氟沙星隐形眼镜光学和溶胀性能的关键变量。研究的自变量是用于制备镜片的单体溶液中加入的 Pluronic F68 浓度(X,%w/v)、包装溶液中的 Pluronic F68 浓度(X %w/v)、单体溶液中加入的载氟沙星浓度(X %w/v)、高压釜中加入的载氟沙星和 Pluronic F68 包装溶液浓度(X,%w/v)、提取过程中加入的载氟沙星和 Pluronic F68 包装溶液浓度(X,%w/v)、单体溶液中加入载氟沙星和 Pluronic F68 后的时间(X,h)、包装溶液的 pH 值(X)、提取溶液的温度(X,°C)和隐形眼镜的固化时间(X,min)。对载氟沙星隐形眼镜进行了光学透过率的测试,分别为灭菌后第 1 天(Y,%)、灭菌后第 7 天(Y,%)和灭菌后第 7 天的溶胀率(Y,%)。所选变量的响应范围分别为 Y、Y 和 Y 的 53.5%至 97.2%、51.3%至 92.6%和 50.3%至 83.7%。数据表明,隐形眼镜内的 Pluronic F68(X)降低了隐形眼镜的光学和溶胀性能,而包装溶液中的 Pluronic F68(X)通过胶束形成改善了这些性能。其他变量(X 至 X)对溶胀率和透过率没有显著影响。本研究表明 Plackett-Burman 设计具有筛选影响载氟沙星隐形眼镜光学和溶胀性能的关键变量的潜力。