Vollmer Tanja, Hinse Dennis, Diekmann Jürgen, Knabbe Cornelius, Dreier Jens
Herz- und Diabeteszentrum Nordrhein-Westfalen, Institut für Laboratoriums- und Transfusionsmedizin, Universitätsklinik der Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
Transfus Med Hemother. 2019 Apr;46(2):111-113. doi: 10.1159/000499543. Epub 2019 Mar 14.
The shelf life of platelet concentrates (PCs) was limited in Germany to 4 days after the day of production because platelet-related septic complications had been observed, mainly with PCs at the end of their shelf life. The reduction in PC shelf life gives rise to several problems, including an increased number of discarded products, accompanied by potential challenges of how to ensure an adequate supply of platelet products. The aim of this study was to show routine experience over the last 7 years using the Bactiflow (BF) assay to screen for bacterial contamination late in PC storage, followed by extension of PC shelf life.