Suppr超能文献

烟雾病患者的体素内不相干运动灌注:与氧气正电子发射断层扫描的比较

Intravoxel incoherent motion perfusion in patients with Moyamoya disease: comparison with O-gas positron emission tomography.

作者信息

Hara Shoko, Hori Masaaki, Ueda Ryo, Hagiwara Akifumi, Hayashi Shihori, Inaji Motoki, Tanaka Yoji, Maehara Taketoshi, Ishii Kenji, Aoki Shigeki, Nariai Tadashi

机构信息

Department of Neurosurgery, Tokyo Medical and Dental University, Tokyo, Japan.

Department of Radiology, Juntendo University, Tokyo, Japan.

出版信息

Acta Radiol Open. 2019 May 23;8(5):2058460119846587. doi: 10.1177/2058460119846587. eCollection 2019 May.

Abstract

BACKGROUND

Intravoxel incoherent motion magnetic resonance imaging (IVIM) enables non-invasive measurement of brain perfusion.

PURPOSE

To investigate whether IVIM could be used to evaluate the hemodynamic disturbance of Moyamoya disease (MMD) by comparison with the gold-standard O-gas positron emission tomography (PET) method.

MATERIAL AND METHODS

Ten consecutive patients with MMD (six women; mean age = 42.8 years) and 10 age-matched healthy controls were evaluated by diffusion-weighted images with 12 different values in the range of 0-900 s/mm and O-gas PET. Tomographic maps of IVIM parameters, perfusion fraction (), pseudo-diffusion coefficient (), and , as well as cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT) maps obtained with PET, were normalized and hemispheric gray and white matter values were calculated. IVIM parametric values were compared with PET parameters and with clinically assessed disease severity.

RESULTS

There was significant correlation between and MTT ( = -0.74,  < 0.001) and between and CBF ( = 0.52,  = 0.02) in the cortical areas. The values in the white matter were significantly higher in symptomatic MMD patients than in healthy controls ( = 0.01).

CONCLUSION

IVIM may be used to non-invasively investigate cerebral hemodynamic impairment in patients with MMD. Further evaluation is needed to establish IVIM usage in clinical settings.

摘要

背景

体素内不相干运动磁共振成像(IVIM)能够对脑灌注进行无创测量。

目的

通过与金标准的氧气正电子发射断层扫描(PET)方法进行比较,研究IVIM是否可用于评估烟雾病(MMD)的血流动力学紊乱。

材料与方法

对连续10例MMD患者(6名女性;平均年龄 = 42.8岁)和10名年龄匹配的健康对照者进行评估,采用在0 - 900 s/mm范围内具有12种不同b值的扩散加权图像以及氧气PET检查。对IVIM参数、灌注分数(f)、伪扩散系数(D *)和D的断层图像,以及通过PET获得的脑血容量(CBV)、脑血流量(CBF)和平均通过时间(MTT)图像进行归一化处理,并计算半球灰质和白质值。将IVIM参数值与PET参数以及临床评估的疾病严重程度进行比较。

结果

在皮质区域,f与MTT之间存在显著相关性(r = -0.74,P < 0.001),D *与CBF之间存在显著相关性(r = 0.52,P = 0.02)。有症状的MMD患者白质中的D *值显著高于健康对照者(P = 0.01)。

结论

IVIM可用于无创性研究MMD患者的脑血流动力学损害。需要进一步评估以确定IVIM在临床环境中的应用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/76a5/6535913/5d50e5bbb66d/10.1177_2058460119846587-fig3.jpg