Suppr超能文献

ACL TOP 自动化分析仪出现凝血错误信息的突然增加。

An abrupt rise of coagulation error messages on ACL TOP automated analysers.

机构信息

Department of Laboratory Medicine, UZ Leuven, Leuven, Belgium.

Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium.

出版信息

Biochem Med (Zagreb). 2019 Jun 15;29(2):021002. doi: 10.11613/BM.2019.021002.

Abstract

INTRODUCTION

Blood coagulation tests (BCT) are very important for clinicians to diagnose bleeding or thrombotic disorders and to monitor anticoagulant therapy.

CASE DESCRIPTION

On a Saturday morning, a laboratory technician noted an abrupt rise in the number of coagulation error messages on our ALC TOP analysers. Visual inspection revealed the presence of partially and/or fully clotted citrate tubes and prompted the clinical biologist to further investigate a potential preanalytical cause.

CONSIDERED CAUSES

Partially or fully clotted blood in citrate tubes can have multiple causes including improper mixing of the tube, under- or overfilling or combining blood samples from different tubes into one citrate tube.

WHAT HAPPENED

The affected citrate tubes originated mostly from the same clinical departments. Moreover, all the affected tubes shared the same lot number (1 of 7 in use at the time). Visual inspection of 7 unopened boxes of 100 citrate tubes of this lot number revealed one box with nine completely empty and two partially filled tubes and one box with two partially filled tubes. No under-filled tubes were found in the other 5 boxes.

DISCUSSION

The blood to additive ratio is crucial for BCT. A sudden rise in clot errors should trigger a thorough investigation to identify the cause.

MAIN LESSON

Laboratories should regularly monitor and evaluate the percentage of clotted samples as a quality indicator at scheduled time points. A problem with the volume of additive in citrate tubes should be considered as a possible cause.

摘要

简介

凝血检测(BCT)对于临床医生诊断出血或血栓形成障碍以及监测抗凝治疗非常重要。

案例描述

一个周六的早上,一位实验室技术员注意到我们的 ALC TOP 分析仪上的凝血错误消息数量突然增加。目视检查发现部分或全部凝结的柠檬酸盐管存在,并促使临床生物学家进一步调查潜在的分析前原因。

考虑的原因

柠檬酸盐管中的部分或全部凝结的血液可能有多种原因,包括管混合不当、填充不足或过量,或者将来自不同管的血液样本混合到一个柠檬酸盐管中。

发生了什么

受影响的柠檬酸盐管主要来自同一临床科室。此外,所有受影响的管都使用了相同的批号(当时使用的 7 批中的 1 批)。对该批号的 7 个未开封的 100 支柠檬酸盐管的目视检查显示,有 1 个盒子有 9 支完全空管和 2 支部分填充管,另 1 个盒子有 2 支部分填充管。在其他 5 个盒子中没有发现填充不足的管。

讨论

血液与添加剂的比例对 BCT 至关重要。凝血错误的突然增加应触发彻底调查以确定原因。

主要教训

实验室应定期监测和评估在预定时间点作为质量指标的凝结样本的百分比。应考虑柠檬酸盐管中添加剂体积的问题作为可能的原因。