矫正牙移动用矫正器产生的力和力矩:系统评价和荟萃分析。

Forces and moments generated by aligner-type appliances for orthodontic tooth movement: A systematic review and meta-analysis.

机构信息

Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece.

Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece.

出版信息

Orthod Craniofac Res. 2019 Nov;22(4):248-258. doi: 10.1111/ocr.12333. Epub 2019 Jul 9.

Abstract

The aim of this review was to systematically appraise the evidence on aligner mechanics and forces and moments generated across difference types of aligners. In vitro- laboratory studies for model simulated tooth movement with aligners. Database searches within Medline via Pubmed, Cochrane Central Register of Controlled Trials (CENTRAL), LILACS via BIREME Virtual Health Library. Unpublished literature was also searched in Open Grey, ClinicalTrials.gov (www.clinicaltrials.gov), the National Research Register (www.controlled-trials.com) and Center for Open Science (Open Science Framework), using the terms "aligner" AND "orthodontic". Risk of bias assessment was based on the Cochrane Risk of Bias tool. Random effects meta-analyses were conducted. A total of 447 studies were identified through electronic search and after careful consideration of pre- defined eligibility criteria, 13 deemed eligible for inclusion, while 2 were included in the quantitative synthesis. When palatal tipping of the upper central incisor through PET-G aligners was considered, aligner thickness of 0.5, 0.625 or 0.75 mm was not associated with a significantly different moment to force (M/F) ratio, given a common gingival edge width of 3-4 mm. Aligner thickness does not appear to possess a significant role in forces and moments generated by clear aligners under specific settings, while the most commonly examined tooth movements are tipping and rotation. The findings of this review may be applicable to certain conditions in laboratory settings.

摘要

本综述的目的是系统评价不同类型的矫正器的力学和产生的力和力矩的证据。体外-实验室研究使用矫正器模拟牙齿移动。在 Medline 通过 Pubmed、Cochrane 中央对照试验注册中心 (CENTRAL)、LILACS 通过 BIREME 虚拟健康图书馆进行数据库检索。还在 Open Grey、ClinicalTrials.gov(www.clinicaltrials.gov)、国家研究登记处(www.controlled-trials.com)和开放科学中心(开放科学框架)中搜索未发表的文献,使用的术语是“矫正器”和“正畸”。偏倚风险评估基于 Cochrane 偏倚风险工具。进行了随机效应荟萃分析。通过电子搜索共确定了 447 项研究,经过仔细考虑预先定义的纳入标准,有 13 项被认为符合纳入标准,而有 2 项被纳入定量综合分析。当考虑通过 PET-G 矫正器对上颌中切牙进行腭倾斜时,在共同的牙龈边缘宽度为 3-4mm 的情况下,0.5、0.625 或 0.75mm 的矫正器厚度与力(M/F)比无显著差异。在特定设置下,矫正器厚度似乎对透明矫正器产生的力和力矩没有显著作用,而最常检查的牙齿运动是倾斜和旋转。本综述的结果可能适用于实验室环境中的某些情况。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验