Suppr超能文献

骨干髁角和外侧肱骨头-肱骨小头角的观察者内和观察者间可靠性:基于不同年龄和经验水平的可靠性评估。

Intra-Observer and Inter-Observer Reliability of Shaft Condylar Angle and Lateral Capitellohumeral Angle: Evaluation Based on Reliability in Different Ages and Levels of Experience.

机构信息

Department of Biochemistry, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.

Department of Orthopaedic Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.

出版信息

Orthop Surg. 2019 Jun;11(3):467-473. doi: 10.1111/os.12489.

Abstract

OBJECTIVES

The aims of this paper were: (i) to examine the intra-observer and inter-observer reliability of the shaft-condylar angle (SCA) and the lateral capitellohumeral angle (LCHA); (ii) to study the influence of experience level on the inter-observer and intra-observer reliability; and (iii) to determine the influence of the the age of the patients on reliability.

METHOD

A retrospective cohort study was conducted. The study reviewed 81 elbow radiographs. The patients were aged between 2 and 13 years. All the images taken between 2000 and 2017 were independently measured by a senior pediatric orthopaedic surgeon, a pediatric orthopaedic surgeon, a pediatric orthopaedic fellow, an orthopaedic chief resident, a general practitioner, and a pediatric orthopaedic research assistant. Measurement was performed two times within a 2-week interval. Inexperienced observers (general practitioner and research assistant) were supervised by senior pediatric orthopaedic surgeons for at least 30 radiographs before performing the measurement. Inclusion criteria were as follows: (i) age 2-13 years; and (ii) no previous elbow fracture.

EXCLUSION CRITERIA

elbow radiographs do not show true lateral view. The intraclass correlation coefficient (ICC) was used to calculate the reliability.

RESULTS

The mean values of SCA and LCHA were 43° and 48°, respectively. For SCA, intra-observer reliability was excellent (ICC = 0.85) for one observer, good (range = 0.73-0.76) for three observers, and moderate (0.59) for one observer. Inter-observer reliability was moderate (0.48, 0.58), whereas the reliability categorized by age group showed excellent agreement (0.88-0.94). For LCHA, intra-observer reliability was excellent (0.84-0.89) for three observers and good (0.66-0.80) for two observers. Inter-observer reliability was moderate (0.44-0.45). Conversely, the reliability classified by age group showed excellent agreement (0.83-0.91).

CONCLUSION

Intra-observer reliability for LCHA and SCA were excellent to good for most observers. Inter-observer reliability was moderate for LCHA and SCA. Reliability classified by age group showed excellent to good agreement. Reliability was influenced by the level of experience, especially for non-medical staff.

摘要

目的

本文旨在:(i)检验轴-髁角(SCA)和外侧肱骨滑车角(LCHA)的观察者内和观察者间可靠性;(ii)研究经验水平对观察者间和观察者内可靠性的影响;以及(iii)确定患者年龄对可靠性的影响。

方法

本研究为回顾性队列研究。研究共评估了 81 例肘关节 X 线片。患者年龄 2-13 岁。所有 X 线片均于 2000 年至 2017 年拍摄,由一名资深小儿矫形外科医生、一名小儿矫形外科医生、一名小儿矫形外科研究员、一名矫形科住院总医师、一名全科医生和一名小儿矫形外科研究助理分别独立测量。两次测量间隔为 2 周。在进行测量之前,经验不足的观察者(全科医生和研究助理)由资深小儿矫形外科医生监督至少 30 次。纳入标准如下:(i)年龄 2-13 岁;(ii)无既往肘关节骨折。

排除标准

肘关节 X 线片不能显示真实的侧位像。使用组内相关系数(ICC)来计算可靠性。

结果

SCA 和 LCHA 的平均值分别为 43°和 48°。对于 SCA,一位观察者的观察者内可靠性为优(ICC=0.85),三位观察者的观察者内可靠性为良(范围=0.73-0.76),一位观察者的观察者内可靠性为中(0.59)。观察者间可靠性为中(0.48,0.58),而按年龄组分类的可靠性显示出极好的一致性(0.88-0.94)。对于 LCHA,三位观察者的观察者内可靠性为优(0.84-0.89),两位观察者的观察者内可靠性为良(0.66-0.80)。观察者间可靠性为中(0.44-0.45)。相反,按年龄组分类的可靠性显示出极好的一致性(0.83-0.91)。

结论

对于大多数观察者而言,LCHA 和 SCA 的观察者内可靠性为优至良。LCHA 和 SCA 的观察者间可靠性为中。按年龄组分类的可靠性显示出极好至良的一致性。可靠性受经验水平的影响,尤其是对非医务人员。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f2ee/6595104/9ad7487aa5e4/OS-11-467-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验