使用新型数字触觉测量仪(光束测试)与Semmes-Weinstein单丝模拟触觉测量仪测量的触觉敏感性比较。

Comparison of tactile sensitivity measured with a new digital esthesiometer (Beam Test) relative to Semmes-Weinstein monofilament analog esthesiometer.

作者信息

Sapa M-C, Sagot J-C, Touvenot G, Xavier F, Hidalgo Diaz J-J, Facca S, Zaré M, Liverneaux P

机构信息

Department of Hand Surgery, SOS hand, CCOM, University Hospital of Strasbourg, FMTS, University of Strasbourg, Icube CNRS 7357, 1, avenue Molière, 67000 Strasbourg, France.

ELLIADD Laboratory (EA n° 4661), UTBM-University of Burgundy Franche-Comté (UBFC), 90010 Belfort cedex, France.

出版信息

Hand Surg Rehabil. 2019 Sep;38(4):242-245. doi: 10.1016/j.hansur.2019.06.003. Epub 2019 Jun 26.

Abstract

The assessment of tactile sensitivity uses many tests, of which monofilaments are considered the best. The aim of this study was to develop a tactile sensitivity test, similar to the monofilament test, which eliminates the error risk related to manipulations by the observer, and to establish a correspondence scale. We studied 29 healthy subjects (18 women and 11 men) with a mean age of 27.8 years. The Semmes-Weinstein monofilament (SWM) analog esthesiometer and a digital beam esthesiometer (DBE) were used. We evaluated the tactile sensitivity threshold on the fingertip of each subject's dominant index using the SWM and the DBE. The DBE test consisted of applying the index against the tip of the beam. During a cycle of four elevations/depressions, the subject would press a button each time he/she felt pressure. The test was repeated three times. The screen displayed an average force value between 0 and 200 allowing the result to be expressed in grams (g). The minimum perceived force was 0.06656g (0.023, 0.166) on average with the SWM test and 0.51773g (0.4824, 0.8062) with the DBE test. Our results confirm the DBE test suppresses the observer's manipulations and that a SWM correspondence scale can be established. With the DBE test, the normal sensation ranged from 0.4824g to 0.757g and light touch decreased from 0.758g to 0.8062g. The threshold value of pathological tactile sensitivity was 0.8063g. The DBE test could therefore be used for preventive diagnosis of carpal tunnel syndrome in occupational medicine.

摘要

触觉敏感性评估采用多种测试方法,其中单丝测试被认为是最佳方法。本研究的目的是开发一种类似于单丝测试的触觉敏感性测试,该测试可消除与观察者操作相关的误差风险,并建立一个对应量表。我们研究了29名健康受试者(18名女性和11名男性),平均年龄为27.8岁。使用了Semmes-Weinstein单丝(SWM)模拟触觉测量仪和数字光束触觉测量仪(DBE)。我们使用SWM和DBE评估了每个受试者优势食指指尖的触觉敏感性阈值。DBE测试包括将食指靠在光束尖端。在四个上升/下降周期中,受试者每次感觉到压力时都会按下按钮。该测试重复三次。屏幕显示0至200之间的平均力值,结果可以用克(g)表示。SWM测试的平均最小可感知力为0.06656g(0.023,0.166),DBE测试为0.51773g(0.4824,0.8062)。我们的结果证实DBE测试抑制了观察者的操作,并且可以建立SWM对应量表。通过DBE测试,正常感觉范围为0.4824g至0.757g,轻触觉从0.758g降至0.8062g。病理性触觉敏感性的阈值为0.8063g。因此,DBE测试可用于职业医学中腕管综合征的预防性诊断。