Balart-Sánchez Sebastián A, Vélez-Pérez Hugo, Rivera-Tello Sergio, Gómez Velázquez Fabiola R, González-Garrido Andrés A, Romo-Vázquez Rebeca
Instituto de Neurociencias, CUCBA, Universidad de Guadalajara, Francisco de Quevedo 180, Arcos Vallarta, C.P. 44130, Guadalajara, Jalisco, Mexico.
Departamento de Ciencias Computacionales, CUCEI, Universidad de Guadalajara, Blvd. Marcelino García Barragán 1421, esq. Calzada Olímpica, C.P. 44430, Guadalajara, Jalisco, Mexico.
Biomed Tech (Berl). 2019 Dec 18;64(6):655-667. doi: 10.1515/bmt-2017-0189.
The aim of this study was to compare a reconfigurable mobile electroencephalography (EEG) system (M-EMOTIV) based on the Emotiv Epoc® (which has the ability to record up to 14 electrode sites in the 10/20 International System) and a commercial, clinical-grade EEG system (Neuronic MEDICID-05®), and then validate the rationale and accuracy of recordings obtained with the prototype proposed. In this approach, an Emotiv Epoc® was modified to enable it to record in the parieto-central area. All subjects (15 healthy individuals) performed a visual oddball task while connected to both devices to obtain electrophysiological data and behavioral responses for comparative analysis. A Pearson's correlation analysis revealed a good between-devices correlation with respect to electrophysiological measures. The present study not only corroborates previous reports on the ability of the Emotiv Epoc® to suitably record EEG data but presents an alternative device that allows the study of a wide range of psychophysiological experiments with simultaneous behavioral and mobile EEG recordings.
本研究的目的是比较一种基于Emotiv Epoc®的可重构移动脑电图(EEG)系统(M-EMOTIV,其能够在10/20国际系统中记录多达14个电极位点)和一种商业临床级EEG系统(Neuronic MEDICID-05®),然后验证所提出原型记录的原理和准确性。在这种方法中,对Emotiv Epoc®进行了修改,使其能够在顶中央区域进行记录。所有受试者(15名健康个体)在连接到这两种设备时执行视觉Oddball任务,以获取电生理数据和行为反应进行比较分析。Pearson相关性分析显示,在电生理测量方面,两种设备之间具有良好的相关性。本研究不仅证实了先前关于Emotiv Epoc®适当地记录EEG数据能力的报告,而且还提出了一种替代设备,该设备允许通过同时进行行为和移动EEG记录来研究广泛的心理生理实验。