Suppr超能文献

比较测量剪切力和肌节长度的方法及其与牛肉最长肌感官嫩度的关系。

Comparison of methods for measuring shear force and sarcomere length and their relationship with sensorial tenderness of longissimus muscle in beef.

机构信息

Faculty of Food Engineering (FEA), Cidade Universitária ZeferinoVaz, University of Campinas (UNICAMP), Campinas, São Paulo, Brazil.

@Tech-Innovation Technology for Agriculture, Piracicaba, São Paulo, Brazil.

出版信息

J Texture Stud. 2020 Apr;51(2):252-262. doi: 10.1111/jtxs.12473. Epub 2019 Aug 6.

Abstract

Slice shear force (SSF) and laser diffraction, considered faster methodologies, for measuring beef instrumental tenderness and sarcomere length, were compared with reference methodologies Warner-Bratzler shear force (WBSF) and phase contrast microscopy. Striploin samples (n = 74) were analyzed for pH, sarcomere length, instrumental tenderness, myofibrillar fragmentation index, and sensorial tenderness. Pearson's correlation measured the association of meat evaluation methods with residual analysis of the multivariate analysis of variance model. The n-dimensional profile to evaluated methods was presented by biplot to identify the behavior of the correlation between the methods (variables). There was moderate correlation between SSF and WBSF (r = .63; p < .01) and both presented moderate correlation with sensorial tenderness (r = - .62 and -.55, to SSF and WBSF, respectively; p < .01). However, WBSF was more efficient to classify samples as tender (68%) than SSF (47%), comparing with sensorial tenderness (80%). There was a moderate correlation for laser and microscopy for sarcomere length (r = .57; p < .01). Sarcomeres were shorter when measured by laser than microscopy. Either with low correlation coefficients, sarcomere measured by laser (r = .29; p < .05) presented higher correlation with sensorial tenderness than with microscopy (r = .22; p < .10). Results highlighted that SSF was faster and easier to run, while WBSF was more appropriate to classify samples by sensorial tenderness grades. Laser diffraction is more suitable to explain effects on tenderness; however, microscopy revealed results of sarcomere length that were more realistic, once laser can underestimate sarcomeres.

摘要

切片剪切力(SSF)和激光衍射,被认为是更快的方法,用于测量牛肉仪器嫩度和肌节长度,与参考方法 Warner-Bratzler 剪切力(WBSF)和相差显微镜进行了比较。牛腰肉样(n = 74)用于分析 pH 值、肌节长度、仪器嫩度、肌原纤维碎片化指数和感官嫩度。Pearson 相关测量了肉品评价方法与多变量方差分析模型残差分析之间的相关性。多维轮廓评价方法通过双标图确定方法(变量)之间相关性的行为。SSF 和 WBSF 之间存在中度相关性(r =.63;p < .01),与感官嫩度都有中度相关性(r = -.62 和 -.55,分别对应 SSF 和 WBSF;p < .01)。然而,与感官嫩度(80%)相比,WBSF 更有效地将样品分类为嫩肉(68%),而 SSF 则更有效(47%)。激光和显微镜在肌节长度方面存在中度相关性(r =.57;p < .01)。用激光测量时,肌节比显微镜测量时更短。用激光测量的肌节(r =.29;p < .05)与感官嫩度的相关性高于用显微镜测量的肌节(r =.22;p < .10),尽管相关系数较低。结果表明,SSF 更快且更容易运行,而 WBSF 更适合根据感官嫩度等级对样品进行分类。激光衍射更适合解释对嫩度的影响;然而,显微镜揭示了肌节长度的结果更现实,因为激光可能会低估肌节。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验