Suppr超能文献

与糖尿病患者使用连续血糖监测相关的人为因素:系统评价。

Human Factors Associated with Continuous Glucose Monitor Use in Patients with Diabetes: A Systematic Review.

机构信息

PhD Program, College of Nursing, University of Florida, Gainesville, Florida.

Division of Pediatric Endocrinology, College of Medicine, University of Florida, Gainesville, Florida.

出版信息

Diabetes Technol Ther. 2019 Oct;21(10):589-601. doi: 10.1089/dia.2019.0136. Epub 2019 Aug 20.

Abstract

Consistent continuous glucose monitor (CGM) use is associated with substantial improvements in glycemic control, yet the uptake and continued use of these technologies remains low. This systematic review aims to identify and summarize the state of science on human factors and their association with CGM use to inform training methods and best practices that support adherence to CGM use and automated insulin delivery systems. A literature search was conducted in PubMed, CINAHL, The Cochrane Library, and PsychInfo databases using PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines to identify studies that reported psychological human factors related to CGM or sensor-augmented pump use in patients with type 1 diabetes. In total, 389 records were identified through our database search and 26 studies published between 2010 and 2017 were included. Articles underwent quality appraisal using the and were categorized according to study outcomes. Identified human factors with a potential association with CGM use were treatment satisfaction, quality of life, emotional distress, and self-efficacy. Eight patient-reported barriers to CGM use were identified as a subcomponent of satisfaction. To date, studies of human factors associated with CGM use generally lack standardized measures and sufficient methodological rigor necessary to establish causation. A more robust understanding of how identified human factors influence CGM use is necessary. Future studies should test interventions that target human factors to improve consistency of use and establish best practices for enhancing patients' experience and acceptance of these technologies, especially within adolescents and young adults.

摘要

持续使用连续血糖监测仪(CGM)与血糖控制的显著改善相关,但这些技术的采用和持续使用仍然很低。本系统评价旨在确定和总结与 CGM 使用相关的人为因素及其关联的科学状态,为培训方法和最佳实践提供信息,以支持 CGM 使用和自动化胰岛素输送系统的依从性。根据 PRISMA(系统评价和荟萃分析的首选报告项目)指南,在 PubMed、CINAHL、Cochrane 图书馆和 PsychInfo 数据库中进行了文献检索,以确定报告与 1 型糖尿病患者 CGM 或传感器增强型泵使用相关的心理人为因素的研究。通过我们的数据库搜索共确定了 389 条记录,纳入了 2010 年至 2017 年期间发表的 26 项研究。使用 进行了文章质量评估,并根据研究结果进行了分类。确定的与 CGM 使用相关的人为因素有治疗满意度、生活质量、情绪困扰和自我效能感。CGM 使用满意度的一个亚组确定了 8 个患者报告的 CGM 使用障碍。迄今为止,与 CGM 使用相关的人为因素研究一般缺乏标准化的测量方法和必要的方法学严谨性,无法确定因果关系。有必要更深入地了解已确定的人为因素如何影响 CGM 使用。未来的研究应测试针对人为因素的干预措施,以提高使用的一致性,并为提高患者对这些技术的体验和接受程度建立最佳实践,尤其是在青少年和年轻人中。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验