There is no worldwide recognized reference system and standard for urinary albumin measurement until now, so the analytical quality from different laboratories has always varied. In this study, we aimed to evaluate the analytical performance of a urinary albumin assay system using Sigma-metric, and thereby choose a suitable control rule to guarantee the analytical quality of the assays.
Two levels of diluted reference material (ERM-DA47OK/IFCC) were used to calculate the biases, the coefficient of variation (CV) were calculated from six months of internal quality control measurements at two levels, and the external quality assessment standard of China for urinary albumin (30%) was used as the total allowable error(TEa).
The Sigma values for quality control levels 1 and 2 were 4.28 and 6.14, leading to recommended Westgard rules of 1/2/R/4 (N = 2, R = 2) and 1(N = 2, R = 1), respectively. Westgard rule 1/2/R/4(N = 2, R = 2) was selected for the quality control of the urinary albumin measurements, and with it, the power function graph showed a high efficacy for determining the detection errors with a probability of false rejection of 1.004% and a probability of error detection of 98.80%.
With a TEa of 30% recommended by the external quality assessment standard of China, Westgard rule 1/2/R/4(N = 2, R = 2) with a high efficacy for determining the detection error is recommended for the quality control of urinary albumin measurements.
目前,全球范围内尚未有被认可的尿蛋白测量参考系统和标准,因此不同实验室的分析质量一直存在差异。本研究旨在使用 Sigma 度量法评估尿白蛋白检测系统的分析性能,并选择合适的控制规则来保证检测的分析质量。
使用两种浓度的稀释参考物质(ERM-DA47OK/IFCC)来计算偏倚,通过六个月在两个浓度水平的室内质量控制测量来计算变异系数(CV),并使用中国尿白蛋白的室间质量评估标准(30%)作为总允许误差(TEa)。
质控水平 1 和 2 的 Sigma 值分别为 4.28 和 6.14,分别推荐使用 Westgard 规则 1/2/R/4(N=2,R=2)和 1(N=2,R=1)。选择 Westgard 规则 1/2/R/4(N=2,R=2)用于尿白蛋白检测的质量控制,通过该规则,幂函数图显示出了高效的检测错误能力,假拒接概率为 1.004%,错误检测概率为 98.80%。