Cortambert F, Putet G, Salle B, Deiber M
Service de Pathologie et de Réanimation Néonatales, Hôpital Edouard-Herriot, Lyon.
Arch Fr Pediatr. 1988 Apr;45(4):243-7.
Seventeen premature babies were ventilated with high frequency oscillation (HFO) for severe hyaline membrane disease. The results were compared to a group of 16 babies ventilated with classical positive pressure ventilation and presenting with hyaline membrane disease of the same severity. The results demonstrated an improvement of the mortality rate with HFO without any significant difference of pulmonary or neurologic complications. Furthermore, a controlled study in order to demonstrate an improvement of this type of ventilation is required.
17名早产婴儿因严重透明膜病接受高频振荡通气(HFO)治疗。将结果与一组16名因同样严重程度的透明膜病接受传统正压通气治疗的婴儿进行比较。结果显示,高频振荡通气降低了死亡率,且肺部或神经并发症无显著差异。此外,还需要进行对照研究以证明这种通气方式的改善效果。