Sun Xiepeng, Hu Longhua, Yang Yong, Ren Fei, Fang Xiang
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui, China.
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui, China.
J Hazard Mater. 2020 Jan 5;381:120913. doi: 10.1016/j.jhazmat.2019.120913. Epub 2019 Jul 22.
Gas temperature of a fire compartment and external facade flame height pose serious hazard upon urban environment and safety, where the window (ventilation) condition has an essential impact. This paper investigates their evolutions with a casement window of various opening angles, which has not been quantified previously although is commonly used practically. Experiments are conducted employing a model-scale fire compartment under different heat release rates with a casement window of various dimensions and opening angles. It is found that the upper-part gas temperature inside the compartment increases, while the critical heat release rate for flame ejection as well as the external facade flame height decreases, with increasing of the window opening angle as it is less than 60 degrees (θ < 60°). Then, all these quantities change little as the window opening angle is further increased (θ ≥ 60°). New non-dimensional models are proposed to describe the evolutions of these quantities based on the derived new length scale according to window dimensions and opening angle. This paper provides for the first time both essential data and new correlations for the gas temperature inside fire compartment and external facade flame height with a casement window.