OBJECTIVE

To determine if low molecular weight synthetic colloid fluids administered to dogs interfere with refractometric estimates of total plasma protein (TPPr) and urine osmolality (UOsm).

STUDY DESIGN

Experimental study.

ANIMALS

Eighteen healthy Greyhound dogs.

METHODS

Anaesthetized Greyhounds subjected to haemorrhage for 60 minutes were given 80 mL kg of Plasma-Lyte 148 (CRYST), or 20 mL kg of hydroxyethyl starch 130/0.4 (HES) or succinylated gelatine (GELO) (n = 6 per group) intravenously over 20 minutes. Refractometric (TPPr) and biuret total plasma protein (TPPb) were measured before haemorrhage (Baseline), at end of shock (Shock), immediately (T20), then 40 minutes (T60), 100 minutes (T120) and 160 minutes (T180) after fluid administration. Urine specific gravity (USG) and UOsm were measured at all time points except T20. Estimated UOsm (eUOsm) was calculated from USG. Bias and limits of agreement (LOA) for TPPr versus TPPb, and eUOsm versus UOsm were calculated at each time point.

RESULTS

For dogs given CRYST and GELO, median TPPr and TPPb decreased in parallel, with a small consistent TPP bias (CRYST range of bias, 0.38-0.67 g dL; GELO range of bias, 0.42-0.58 g dL). Dogs given HES showed divergence between median TPPr and TPPb after T20, with a peak bias at T20 of 1.62 g dL (LOA 1.29-1.95). Dogs given HES and GELO had markedly increased USG [HES peak median USG at T180 of 1.119 (Q1-Q3 1.103-1.122); GELO peak median USG at T120 of 1.114 (Q1-Q3 1.082-1.119)], with large increases in bias between eUOsm and UOsm [HES peak bias at T60 of 2995 mOsm kg (LOA 2032-3958 mOsm kg); GELO peak bias at T120 of 2465 mOsm kg (LOA 940-3990 mOsm kg)].

CONCLUSIONS AND CLINICAL RELEVANCE

Administration of HES and GELO to dogs with haemorrhagic shock interferes with refractometric measurements for at least 3 hours after administration.

摘要

目的

确定给犬输注低分子量合成胶体液是否会干扰血浆总蛋白(TPPr)和尿渗透压(UOsm)的折射测定。

研究设计

实验研究。

动物

18只健康灵缇犬。

方法

对麻醉的灵缇犬进行60分钟出血,然后在20分钟内静脉输注80 mL/kg的平衡液(CRYST),或20 mL/kg的羟乙基淀粉130/0.4(HES)或琥珀酰明胶(GELO)(每组n = 6)。在出血前(基线)、休克结束时(休克)、输注后即刻(T20)、然后在输注后40分钟(T60)、100分钟(T120)和160分钟(T180)测量折射法测定的血浆总蛋白(TPPr)和双缩脲法测定的血浆总蛋白(TPPb)。除T20外,在所有时间点测量尿比重(USG)和尿渗透压(UOsm)。根据USG计算估计尿渗透压(eUOsm)。计算每个时间点TPPr与TPPb以及eUOsm与UOsm的偏差和一致性界限(LOA)。

结果

对于输注CRYST和GELO的犬,TPPr和TPPb中位数平行下降,TPP偏差较小且一致(CRYST偏差范围为0.38 - 0.67 g/dL;GELO偏差范围为0.42 - 0.58 g/dL)。输注HES的犬在T20后TPPr和TPPb中位数出现差异,T20时偏差峰值为1.62 g/dL(LOA为1.29 - 1.95)。输注HES和GELO的犬USG显著升高[HES在T180时USG峰值中位数为(四分位间距)1.119(1.103 - 1.122);GELO在T120时USG峰值中位数为1.114(1.082 - 1.119)],eUOsm与UOsm之间的偏差大幅增加[HES在T60时偏差峰值为2995 mOsm/kg(LOA为2032 - 3958 mOsm/kg);GELO在T