Biomechanical evaluation of suture buttons versus cortical screws in the Latarjet-Bristow procedure: a fresh-frozen cadavers study.

机构信息

Division of Orthopaedic Surgery, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Weizman Street, 6423906, Tel Aviv, Israel.

出版信息

Arch Orthop Trauma Surg. 2019 Dec;139(12):1779-1783. doi: 10.1007/s00402-019-03269-6. Epub 2019 Aug 28.

Abstract

INTRODUCTION

A commonly used method of fixation of the transferred coracoid in the traditional Latarjet-Bristow procedure (open or arthroscopic) is by two bicortical screws. Although mechanically effective, screw fixation is also a major source of hardware and neurologic complications. This study aimed to compare the biomechanical performances of traditional metal screws and endobuttons as fixators of the Latarjet-Bristow procedure.

MATERIALS AND METHODS

Nine fresh-frozen cadaveric human scapulae with the conjoined tendon attached to the coracoid process were used for the Latarjet-Bristow procedure. The specimens were randomly assigned one of two groups: fixation using two 4.5-mm cannulated partially threaded Latarjet-Bristow experience screws or fixation using a suture-button construct. Specimens were secured in a material testing machine and cyclically preconditioned from 2 to 10 N at 0.1 Hz for ten cycles. They were then pulled to failure at a normalized displacement rate of 400% of the measured gauge length per minute. The maximal load-to-failure, stiffness and stress were calculated using a custom script. The failure mechanism and site were recorded for each specimen.

RESULTS

There were no significant differences in the maximal load-to-failure or other biomechanical properties of the two fixation techniques, but the failure mechanisms were unique to each one. Four specimens fixated with screws underwent graft failures (fracture) through the proximal or distal drill hole. Five specimens fixated with endobuttons underwent failure due to glenoid bone fractures.

CONCLUSIONS

A single endobutton fixation appears to be biomechanically comparable to screw fixation in the Latarjet-Bristow procedure and provides a lower risk for graft fracture. Further studies with more numerous specimens are warranted to conclusively validate these findings.

摘要

简介

在传统的 Latarjet-Bristow 手术(开放或关节镜)中,将移植物的喙突固定的常用方法是使用两个皮质骨螺钉。虽然机械效果良好,但螺钉固定也是硬件和神经并发症的主要来源。本研究旨在比较传统金属螺钉和 Endobutton 作为 Latarjet-Bristow 手术固定器的生物力学性能。

材料和方法

使用附有喙突肌腱的 9 个新鲜冷冻的人肩胛骨尸体进行 Latarjet-Bristow 手术。标本随机分为两组:使用两个 4.5mm 空心半螺纹 Latarjet-Bristow 经验螺钉或使用缝线纽扣固定。将标本固定在材料试验机上,以 0.1Hz 的频率从 2 到 10N 进行循环预条件化,共 10 个循环。然后以每分钟测量标距的 400%的标准化位移速率将其拉至失效。使用自定义脚本计算最大失效负载、刚度和应力。记录每个标本的失效机制和部位。

结果

两种固定技术的最大失效负载或其他生物力学特性均无显著差异,但失效机制各有特点。使用螺钉固定的 4 个标本经历了移植物在近端或远端钻孔处的失效(骨折)。使用 Endobutton 固定的 5 个标本由于肩胛骨关节骨折而失效。

结论

单个 Endobutton 固定似乎在生物力学上与 Latarjet-Bristow 手术中的螺钉固定相当,并且降低了移植物骨折的风险。需要更多标本的进一步研究来明确验证这些发现。