Clinic for Operative Dentistry, Periodontology and Preventive Dentistry, RWTH University Aachen, Aachen, Germany.
Clinic for Operative Dentistry, Periodontology and Preventive Dentistry, RWTH University Aachen, Aachen, Germany.
Photodiagnosis Photodyn Ther. 2019 Dec;28:75-79. doi: 10.1016/j.pdpdt.2019.08.030. Epub 2019 Aug 27.
Diode lasers are commonly used for antimicrobial photodynamic therapy (aPDT). This study aimed to assess the feasibility of transgingival laser irradiation during aPDT and evaluate whether the photosensitizer can be activated.
Four diode laser settings were assessed for transgingival irradiation: 120 mW, 80 mW, 60 mW, and 40 mW. Fifteen soft-tissue pieces from a pig's lower jaw were prepared. The specimens' thickness was measured and transgingival laser irradiation was performed. A digital power meter measured laser power on the other side of the tissue. The power outcome after staining of the nonbuccal aspect of the tissue with photosensitizer dye was assessed similarly.
Transgingival laser irradiation (average soft-tissue thickness: 0.84 ± 0.06 mm) resulted in different power transmission depending on the power settings and photosensitizer. The lowest values were observed with the 40 mW setting and photosensitizer (median 3.3 mW, max. 5.0 mW, min. 2.3 mW, interquartile range 1.2), and the highest at 120 mW without photosensitizer (median 41.3 mW, max. 42.7 mW, min. 38.0 mW; interquartile range 1.5).
This study indicates that transgingival irradiation may be suitable for aPDT, since power transmission through the gingival tissue was observed in all specimens. However, the decrease in laser power caused by both the soft tissue and the photosensitizer has to be taken into account.
二极管激光常用于抗菌光动力疗法(aPDT)。本研究旨在评估 aPDT 期间经牙龈激光辐照的可行性,并评估光敏剂是否可以被激活。
评估了四种二极管激光设置用于经牙龈辐照:120mW、80mW、60mW 和 40mW。从猪的下颌制备了 15 个软组织样本。测量标本的厚度并进行经牙龈激光辐照。数字功率计在组织的非颊侧测量激光功率。类似地,评估了用光敏剂染料对组织非颊侧进行染色后的功率结果。
经牙龈激光辐照(平均软组织厚度:0.84±0.06mm)导致不同的功率传输,具体取决于功率设置和光敏剂。40mW 设置和光敏剂观察到的最低值(中位数 3.3mW,最大值 5.0mW,最小值 2.3mW,四分位距 1.2),而无光敏剂时在 120mW 时最高(中位数 41.3mW,最大值 42.7mW,最小值 38.0mW;四分位距 1.5)。
本研究表明,经牙龈辐照可能适用于 aPDT,因为在所有标本中都观察到了牙龈组织的功率传输。然而,必须考虑到软组织和光敏剂都会导致激光功率下降。