Nagy L, Lakatos T, Tegzes L
Acta Biochim Biophys Acad Sci Hung. 1978;13(4):299-306.
The temperature dependence of the conduction velocity of excitation was investigated in frog sciatic nerve trunk. A specific electronic circuitry was used to measure the time of conduction between two electrodes with an accuracy of +/- microseconds in the temperature range of 5--30 degrees C. Our experiments have proved that the conduction velocity depended linearly on temperature. The slope of the curve was similar at both increasing and decreasing temperature, and "hysteresis" occurred only if irreversible changes occurred in the preparation during the experimental procedure.
在蛙坐骨神经干中研究了兴奋传导速度的温度依赖性。使用一种特定的电子电路来测量两个电极之间的传导时间,在5 - 30摄氏度的温度范围内,精度可达±微秒。我们的实验证明,传导速度与温度呈线性关系。在温度升高和降低时,曲线的斜率相似,并且只有在实验过程中标本发生不可逆变化时才会出现“滞后现象”。